Effect of thermal control of dry fomites on regulating the survival of human pathogenic bacteria responsible for nosocomial infections


Authors: Tomoko Shimoda aff001;  Torahiko Okubo aff002;  Yoshiki Enoeda aff001;  Rika Yano aff001;  Shinji Nakamura aff003;  Jeewan Thapa aff002;  Hiroyuki Yamaguchi aff002
Authors place of work: Department of Fundamental Nursing, Faculty of Health Sciences, Hokkaido University, Sapporo, Japan aff001;  Department of Medical Laboratory Science, Faculty of Health Sciences, Hokkaido University, Sapporo, Japan aff002;  Laboratory of Morphology and Image Analysis, Biomedical Research Center, Juntendo University Graduate School of Medicine, Tokyo, Japan aff003
Published in the journal: PLoS ONE 14(12)
Category: Research Article
doi: https://doi.org/10.1371/journal.pone.0226952

Summary

We monitored the survival of human pathogenic bacteria [Escherichia coli (ATCC), extended-spectrum β-lactamase-producing E. coli (Clinical isolate), New Delhi metallo-β-lactamase-producing E. coli (clinical isolate), Staphylococcus aureus (ATCC)] on dry materials (vinyl chloride, aluminum, plastic, stainless steel) at distinct temperatures (room temperature or 15°C–37°C). These bacteria favored a lower temperature for their prolonged survival on the dry fomites, regardless of the material type. Interestingly, when mixed with S. aureus, E. coli survived for a longer time at a lower temperature. Cardiolipin, which can promote the survival of S. aureus in harsh environments, had no effect on maintaining the survival of E. coli. Although the trends remained unchanged, adjusting the humidity from 40% to 60% affected the survival of bacteria on dry surfaces. Scanning electron microscopic analysis revealed no morphological differences in these bacteria immediately before or after one day of dry conditions. In addition, ATP assessment, a method used to visualize high-touch surfaces in hospitals, was not effective at monitoring bacterial dynamics. A specialized handrail device fitted with a heater, which was maintained at normal human body core temperature, successfully prohibited the prolonged survival of bacteria [Enterococcus faecalis (ATCC), E. coli (ATCC), Pseudomonas aeruginosa (ATCC), S. aureus (ATCC), Acinetobacter baumannii (clinical isolate), and Serratia marcescens (clinical isolate)], with the exception of spore-forming Bacillus subtilis (from our laboratory collection) and the yeast-like fungus Candida albicans (from our laboratory collection)] on dry surfaces. Taken together, we concluded that the tested bacteria favor lower temperatures for their survival in dry environments. Therefore, the thermal control of dry fomites has the potential to control bacterial survival on high-touch surfaces in hospitals.

Keywords:

Bacterial pathogens – Staphylococcus aureus – Stainless steel – Body temperature – Nosocomial infections – Enterococcus faecalis – Humidity – Chlorides

Introduction

Strategies to ensure greater control of hospital-acquired infections are urgently needed. Microbe-contaminated dry surfaces in hospitals that are frequently touched by hands, termed ‘high-touch’ surfaces, such as handrails, doorknobs, lockers, and the table surfaces of inpatients, present a high risk in terms of the spread of nosocomial infections [13]. It is well recognized that improved hand hygiene and cleaning of surfaces are critically important in controlling hospital-acquired infections [46]. While improved cleaning practices have led to a decrease in the transmission of hospital-acquired infections [79], in general, hospital cleanliness is still not sufficient to control infections [1012]. This is confirmed by the fact that outbreaks of hospital-acquired infections still occur worldwide [1315]. It is therefore possible that there are other unknown factors responsible for bacterial survival, particularly on dry surfaces, in hospitals.

We previously monitored hospital cleanliness on the surfaces of 752 sites in nurse and patient areas in three hospitals located in the central area of Sapporo, Japan, and revealed the presence of a wide range of organic contamination, including microbial contamination, that could be spread via hand touching [1618]. Considerable variability in bacterial detection was noted, even for the same surfaces, indicating that the ongoing cleanliness of dry surfaces in hospitals is insufficient [1618]. Furthermore, accumulating evidence indicates that various human pathogenic bacteria (such as Pseudomonas, Acinetobacter, Enterococcus, Staphylococcus, and Enterobacteriaceae), including multidrug-resistant bacteria, can survive for prolonged periods on dry surfaces [1925]. The reason for the variability in bacterial detection remains unclear, but changing physiological factors such as environmental temperature may affect bacterial survival. Whether thermal control can regulate bacterial survival in dry environments remains unknown.

In this study, we monitored the survival of human pathogenic bacteria [Escherichia coli ATCC, extended-spectrum β-lactamase (ESBL)-producing E. coli, New Delhi metallo-β-lactamase (NDM)-producing E. coli, and Staphylococcus aureus ATCC] on dry materials (vinyl chloride, aluminum, plastic, stainless steel) over a range of temperatures (room temperature to 37°C). We found that bacteria favor lower temperatures for survival in dry environments. Furthermore, we propose that fomites warmed to human body core temperature may help to control bacterial survival in dry environments, and that such a strategy may prohibit the emergence of human pathogenic bacteria in hospital environments, eventually reducing the need for antibiotics as well as disinfectants.

Materials and methods

Bacterial strains

The bacterial strains used in this study were as follows: E. coli ATCC 25922, ESBL-producing E. coli, NDM-producing E. coli [26], and S. aureus ATCC 29213. All of the bacteria were maintained on LB agar plates (Nakalai Tesque Inc., Kyoto, Japan) with or without appropriate antibiotics at 37°C. Both the antimicrobial-resistant E. coli strains were isolated at Hokkaido University Hospital. The reference strains were purchased from the American Type Culture Collection (ATCC, Manassas, VA, USA). E. coli DH5α carrying GFP-expressing plasmid (pBBR122 encoding gfp) was also used for this study [27]. E. coli DH5α was maintained on LB agar with chloramphenicol (10 μg per ml) to maintain the plasmid. Pseudomonas aeruginosa ATCC29213 and Enterococcus faecalis ATCC29212 were also purchased from the ATCC. Acinetobacter baumannii and Serattia marcescens were isolated from Hokkaido University Hospital. Bacillus subtilis and the yeast-like fungus Candida albicans from our laboratory collection were also used for this study. All bacterial strains (except for E. faecalis) and the yeast-like fungus were maintained on LB agar and PDA agar, respectively. Because of requiring more nutrients, E. faecalis was maintained on BHI agar.

Assessment of bacterial dynamics on vinyl chloride

S. aureus ATCC 29213 and E. coli ATCC 25922 were separately adjusted in PBS at approximately 107 CFU per ml, and were either mixed or maintained separately in LB broth. Then, 20 μl of each solution (5.0 × 105 CFU/spot) was spotted onto vinyl chloride material (3 × 3 cm) that is used commercially for flooring and roofing (thanks to TOLI Corporation, Osaka, Japan and TAJIMA ROOFING, Tokyo, Japan). The bacterial solution was left to dry and then incubated at room temperature (~20°C) or in an incubator (30°C and 37°C) for up to 11 days. In some experiments, the bacterial suspensions were dried onto the material with cardiolipin (1 or 100 μM). After incubation, the dried spots were wiped with cotton swabs, and suspended in PBS. The bacteria were enumerated by spreading onto Mannitol salt agar (for culturing of S. aureus) and MacConkey agar (for culturing of E. coli), and bacterial numbers were expressed as CFUs per spot. The spots of bacteria on the dry material were also visualized by SEM observations (see below). The amounts of ATP in each spot were monitored by a Clean-Trace Luminometer 3M (Saint Paul, MN, USA), and the values were expressed as bioluminescence relative light units (RLUs), according to a previously described protocol [17].

Assessment of bacterial dynamics on the other dry fomites (aluminum, plastic, stainless steel)

The survival of S. aureus ATCC 29213 and E. coli ATCC 25922 was also tested on other materials (10 × 10 cm; aluminum, plastic, stainless steel) at a range of temperatures (15°C, 30°C, 37°C) for up to 11 days. Bacterial numbers were evaluated as stated above. Some experiments on plastic were adjusted to a constant humidity of 40%–60% by placing a 100-mL beaker filled with water into the incubator. However, unfortunately, we were unable to maintain a uniform humidity in this way. The humidity of the incubator without the beaker was less than 20%. Humidity was measured with a general hygrometer.

Dynamics of multidrug-resistant E. coli on dry fomite (vinyl chloride)

The dynamics of both ESBL- and NDM-producing E. coli strains with or without S. aureus ATCC 29213 on vinyl chloride material were also assessed. The bacteria were dried and then incubated at distinct temperatures (15°C, 30°C, 37°C) for up to 11 days. Bacterial numbers were evaluated as stated above.

Scanning electron microscopic (SEM) analysis

According to a previously reported method [17], the vinyl chloride material (1 × 1 cm) spotted with bacteria was washed with saline, fixed with 2.5% (v/v) glutaraldehyde in phosphate-buffered saline (pH 7.4) for 2 h at room temperature, then treated with 2% (w/v) osmium tetroxide for 1 h at 4°C. The samples were then dehydrated in ethanol, freeze-dried, and coated with osmium using a plasma osmium coater, for analysis using a scanning electron microscope (Hitachi S-4800; Hitachi, Tokyo, Japan).

Bacterial dynamics on the heated handrail device

A stainless steel handrail pipe (diameter, 13 mm; thickness, 2 mm) equipped with a heater wire in the center of pipe to control the dry surface at body core temperature was constructed using an acrylic-processing assembly kit from FabCloud (Tokyo, Japan). Bacterial dynamics on this surface were assessed as follows. In brief, the GFP-expressing E. coli DH5α were spotted at regular intervals (1 cm) onto the handrail device with or without the heater at approximately 106 CFU per spot (10 μl per spot). The handrail device (with or without heat control) was then incubated at room temperature for one day. The dried spots were wiped with cotton swabs, and suspended into PBS. The number of bacteria was evaluated by the GFP signals after spotting onto LB or MacConkey agar plates containing chloramphenicol, and was expressed as CFUs per spot. In addition, the surface temperature on the handrail pipe was monitored using a hand-held infrared sensor (CT-2000D; Custom Co., Ltd., Tokyo, Japan) and a high-resolution infrared sensor (InfReC R300; NEC Avio Infrared Technologies Co., Ltd., Tokyo, Japan) installed with appropriate software (InfReC Analyzer NS9500; NEC Avio Infrared Technologies Co., Ltd.). We also assessed whether the heated handrail device could work for the illumination of the other bacteria (S. aureus, P. aeruginosa, E. faecalis, A. baumannii, S. marcescens and B. subtilis) and the yeast-like fungus (C. albicans). As mentioned above, the survival of bacteria (P. aeruginosa, A. baumannii, and B. subtilis) and the yeast-like fungus after drying on the device was monitored on LB agar and PDA agar, respectively. The survival of S. aureus and S. marcescens was also monitored on Mannitol salt agar and MacConkey agar, respectively. Meanwhile, because of requiring more nutrients, E. faecalis was monitored on BHI agar.

Statistical analysis

Multiple comparisons of the data were assessed by Bonferroni/Dunn analysis. A p value of <0.05 was considered statistically significant. All calculations were conducted using Excel for Mac (2011) with Statcel3C.

Results

Representative human pathogenic bacteria favor lower temperatures for their survival under dry conditions

To assess the survival of representative human pathogens under dry conditions, we monitored changes in bacterial numbers [E. coli (ATCC 25922), S. aureus (ATCC 29213), or a mixture of these bacteria (because it is possible that they are found together on ‘high-touch’ surfaces)] on vinyl chloride, a widely used material in everyday items, at distinct temperatures [room temperature (around 20°C), 30°C, 37°C] for 11 days. Bacterial numbers were assessed using the following indicators: the number of colony-forming units (CFUs), the amount of ATP, and morphological changes (as determined by SEM analysis) (Fig 1A). Immediately (within 20 min) after drying, the CFU numbers of E. coli, but not S. aureus, showed a two-log reduction; however, both bacteria, either singularly or in a mixture, survived and retained the potential to be spread (Fig 1B). The number of CFUs decreased dramatically over time for both bacteria on dry surfaces, but this trend was amplified by an increase in temperature (Fig 1C). Interestingly, the presence of S. aureus appeared to enhance the survival of E. coli in the bacterial mixture compared with E. coli alone (Fig 1C, See ‘†’). SEM observations revealed that the morphological changes in both bacteria, singularly or in a mixture, one day after drying was minimal, supporting the CFU assay results and indicating survival of both bacteria (Fig 2). ATP assessment revealed no significant differences for either bacteria with varying temperature (S1 Fig). Also, cardiolipin, an agent that aids the survival of S. aureus in dry environments [28, 29], did not support the survival of E. coli after drying, suggesting the presence of another mechanism independent of cardiolipin (S2 Fig). In addition, although the trend observed with altered temperature did not change, humidity control (40–60%) had the opposite effect on the survival of microorganisms on dry surfaces (S3 Fig). Specifically, while the humidity control weakened the thermal effect on the survival of S. aureus on dry environments, a synergistic effect of inhibition on the survival of E. coli was observed. Thus, our findings showed that these bacteria favor a lower temperature for their survival in dry environments, and humidity has a lesser effect.

Representative human pathogenic bacteria favor lower temperatures for their survival on vinyl chloride surfaces.
Fig. 1. Representative human pathogenic bacteria favor lower temperatures for their survival on vinyl chloride surfaces.
A. Experimental protocol. Bacterial survival was monitored for mixed or single bacteria on vinyl chloride at distinct temperatures [RT (around 20°C), 30°C, 37°C] for 11 days by a CFU assay (CFU), ATP assessment (ATP) and morphological changes (SEM). Ec, E. coli (ATCC 25922). Sa, S. aureus (ATCC 29213). B. Bacterial numbers immediately (within 20 min) after drying. Ec, E. coli (ATCC 25922). Sa, S. aureus (ATCC 29213). C. Changes in bacterial numbers at distinct temperatures [RT (around 20°C), 30°C, 37°C] over 11 days, as determined by a CFU assay. Ec, E. coli (ATCC 25922). Sa, S. aureus (ATCC 29213). *, p<0.05 vs. the values at room temperature. **, p<0.05 vs. 30°C. †, p<0.05 between the bars.
Representative SEM images showing bacterial morphologies on vinyl chloride surfaces.
Fig. 2. Representative SEM images showing bacterial morphologies on vinyl chloride surfaces.
E. coli alone (A, D, G). S. aureus alone (B, E, H). Mixture of E. coli with S. aureus (C, F, I). Scale bars in panels, 1 μm (D, G), 2 μm (F, H, I) and 3 μm (A, B, C, E). RT, room temperature.

Differences in the surface material had no effect on bacterial survival (including multidrug-resistant bacteria) in dry environments over a range of temperatures

Next, to confirm whether the effect of temperature on bacterial survival on dry surfaces is universal regardless of the material surface, we monitored changes in bacterial numbers [E. coli (ATCC 25922), S. aureus (ATCC 29213), or a mixture] on a range of common materials (vinyl chloride, aluminum, plastic, stainless steel) at distinct temperatures (15°C, 30°C, 37°C) for 11 days, by assessing the CFU numbers (Fig 3A). Immediately (approximately 1 h) after drying, no differences in bacterial numbers were detected between the different materials (Fig 3B). Although the CFU numbers of both bacteria dramatically reduced over subsequent days on the dry surfaces, this temperature-dependent trend was unaffected by the type of material surface (Fig 3C). Thus, the material itself (vinyl chloride, aluminum, plastic, stainless steel) had no effect on the diminishing bacterial numbers under dry conditions. We also assessed whether the same trend was seen for multidrug-resistant human pathogenic bacteria using ESBL- and NDM-producing E. coli isolated from Hokkaido University Hospital. The CFU assay confirmed increased survival of multidrug-resistant bacteria at lower temperature, as well as increased survival in the presence of S. aureus (Fig 4). Taken together, we conclude that bacteria favoring a lower temperature for their survival in dry environments is a universal phenomenon, which is unaffected by the surface material or bacterial type. Importantly, our data highlighted the potential for controlling the survival of bacteria on high-touch dry surfaces by warming dry fomites to human body core temperature.

Representative human pathogenic bacteria favor lower temperatures for their survival on other surfaces (aluminum, plastic, stainless steel).
Fig. 3. Representative human pathogenic bacteria favor lower temperatures for their survival on other surfaces (aluminum, plastic, stainless steel).
A. Experimental protocol. Bacterial survival was monitored for mixed or single bacteria on other surfaces (aluminum, plastic, stainless steel) at distinct temperature (15°C, 30°C, 37°C) for 11 days by a CFU assay (CFU). Ec, E. coli (ATCC 25922). Sa, S. aureus (ATCC 29213). B. Bacterial numbers immediately (within 20 min) after drying. Ec, E. coli (ATCC 25922). Sa, S. aureus (ATCC 29213). C. Changes in bacterial numbers at distinct temperatures (15°C, 30°C, 37°C) over 11 days, as determined by a CFU assay. Ec, E. coli (ATCC 25922). Sa, S. aureus (ATCC 29213). *, p<0.05 vs. the values at room temperature. **, p<0.05 vs. 30°C.
Representative multidrug-resistant bacteria also favor lower temperatures for their survival on plastic surfaces.
Fig. 4. Representative multidrug-resistant bacteria also favor lower temperatures for their survival on plastic surfaces.
A. Experimental protocol. Bacterial survival was monitored for mixed or single bacteria on plastic surfaces at distinct temperatures (15°C, 30°C, 37°C) for 11 days by a CFU assay (CFU). Ec (ESBL), ESBL-producing E. coli. Ec (NDM), NDM-producing E. coli. Sa, S. aureus (ATCC 29213). B. Bacterial numbers immediately (within 20 min) after drying. Ec (ESBL), ESBL-producing E. coli. Ec (NDM), NDM-producing E. coli. Sa, S. aureus (ATCC 29213). C. Changes in bacterial numbers at distinct temperatures (15°C, 30°C, 37°C) over 11 days, as determined by a CFU assay. Ec (ESBL), ESBL-producing E. coli. Ec (NDM), NDM-producing E. coli. Sa, S. aureus (ATCC 29213). *, p<0.05 vs. the values at room temperature. †, p<0.05 between the bars.

Handrail device warmed to human body core temperature prohibited the prolonged survival of E. coli on this dry surface

To test this possibility, we constructed a stainless steel handrail pipe (diameter, 13 mm; thickness, 2 mm) equipped with a heater wire in the center of the pipe to control the dry surface to body core temperature (S4A Fig). Assessment with a hand-held infrared sensor showed that the surface temperature on the handrail pipe was controlled to almost body core temperature, although the temperature on the device surface varied from the end to the center of the pipe (range: 30°C–40°C) (S4B Fig). A heatmap generated with the high-resolution infrared sensor showed that in contrast to the stainless steel pipe without the heater, the surface temperature on the heated pipe was maintained at body core temperature (Fig 5A), indicating that it is an effective tool to monitor the influence of temperature on bacterial survival on a dry surface. We monitored the survival of GFP-expressing E. coli (DH5α) spotted onto the handrail surface at regular intervals (1 cm) compared with the GFP signals at equivalent spots on an LB agar plate, and assessed CFU numbers. GFP signals were dramatically decreased on the heated handrail compared with the unheated handrail even 6 h after drying, and the signals were virtually undetectable one day after drying (Fig 5B). Consistent with this, the CFU numbers on the heated handrail were significantly reduced compared with those on the unheated handrail (Fig 5C). In addition, we assessed whether the warming handrail could work on other bacteria. The results indicated that the prolonged survival of bacteria (E. faecalis, S. aureus, P. aeruginosa, A. baumannii, and S. marcescens) as well as E. coli, was significantly prohibited, although no effective elimination of the spore-forming bacterium (B. subtilis) was detected (Fig 6). We also confirmed that the yeast-like fungus (C. albicans) failed to survive immediately (within 6 h) after drying on the device (S5 Fig). Taken together, we concluded that the handrail device warmed to human body core temperature prohibited the prolonged survival of some bacteria and a yeast-like fungus responsible for nosocomial infections on a dry surface.

Handrail device warmed to human body core temperature prohibited the prolonged survival of GFP-expressing <i>E</i>. <i>coli</i> on a stainless steel surface.
Fig. 5. Handrail device warmed to human body core temperature prohibited the prolonged survival of GFP-expressing E. coli on a stainless steel surface.
A. Heatmaps of the handrail device with or without a heater. The heatmaps were constructed using a high-resolution infrared sensor (InfReC R300) installed with appropriate software (InfReC Analyzer NS9500). B. Representative images showing decreasing GFP-signals for the bacteria collected from the stainless steel surface warmed by the heater. Numbers show the sampling positions on the pipe. Heater (-), handrail device without heater. Heater (+), handrail device with heater. C. Comparison of the bacterial CFU numbers on the stainless steel device with and without the heater. Black and white bars show the CFU values for the device with and without the heater. *, p<0.05 between the bars.
Handrail device warmed to human body core temperature prohibited the prolonged survival of other bacteria without spore formation on a stainless steel surface.
Fig. 6. Handrail device warmed to human body core temperature prohibited the prolonged survival of other bacteria without spore formation on a stainless steel surface.
The other bacteria (E. faecalis, S. aureus, P. aeruginosa, A. baumannii, S. marcescens and B. subtilis) were used for this study (see the Materials and methods). Images obtained at 24 h after drying correspond to representative bacterial images showing the effect of thermal control on survival of each of the bacteria on the handrail device. Numbers (1–10) indicate bacterial spots. Graphs (right) show a comparison of the bacterial CFU numbers on the stainless steel device with [Heater(+)] and without the heater [Heater(-)]. Black and white bars show the CFU values for the device with and without the heater. *, p<0.05 between the bars. NS, no significant difference.

Discussion

Currently, in the US, an estimated 2 million hospital-acquired infections are reported annually, associated with $5 billion of additional healthcare costs. The control of nosocomial infections is therefore a priority for healthcare providers worldwide [30]. Here, we showed, for the first time, that a lower temperature is favored for the survival of both E. coli and S. aureus on dry fomites. We also demonstrated that a handrail device warmed to human body core temperature could prohibit the prolonged survival of several pathogens responsible for nosocomial infection (E. coli, S. aureus, E. faecalis, P. aeruginosa, A. baumannii and S. marcescens) and a yeast-like fungus (C. albicans) on this dry surface. Innovations such as the development of heated fomites, for example, heated handrails or doorknobs, may prevent the survival of bacteria responsible for nosocomial infections on dry hospital environments, without the need for disinfectants.

It is well established that decreasing environmental temperature has a significant impact on the survival of pathogens in soil or water, sometimes leading to bacterial persistence [3133], but whether temperature influences bacterial survival on artificial materials, such as dry fomites in hospitals, remained unknown. Other factors such as UV radiation, humidity, the presence of organic materials, and surface type are known to be associated with the ability of bacteria responsible for hospital-acquired infections to survive on dry surfaces [3436]; however, temperature is a factor that can be easily and accurately controlled. Furthermore, a temperature of 37°C, which is the core body temperature, is a comfortable temperature that is not harmful to the touch [37]. For these reasons, we selected temperature as a critical factor to study its effects (in particular, body core temperature) on bacterial dynamics and survival on dry fomites.

The numbers of CFUs of both bacteria (E. coli and S. aureus), regardless of whether or not they carried multidrug-resistant genes, were dramatically reduced during the days after drying, and this decrease in bacterial numbers was significantly promoted by increased temperature. Because water evaporation from bacterial cells can be accelerated on dry fomites at high temperature, we speculate that it is difficult for bacteria to maintain metabolic activity under such conditions; thus, their viability decreases. We found that Gram-positive S. aureus could survive longer than Gram-negative E. coli, potentially indicating that cell wall thickness plays a role in prolonging the survival of S. aureus on dry fomites. At lower temperature, E. coli survived for a few days whereas S. aureus survived for over 10 days. Although the survival period for these bacteria is limited, particularly for E. coli, it is still sufficient time for these bacteria to transfer from person to person via high-touch surfaces.

Because of its ease of monitoring, ATP bioluminescence has been employed as a visual indicator of general organic contamination of high-touch surfaces in hospitals [3842]. However, our assessment of ATP showed that, in contrast to the CFU assay, no significant differences in ATP were associated with changes in temperature. Evidence from our previous studies suggests that ATP may be physically stable at a range of temperatures [16, 17]. Furthermore, ATP derived not only from bacteria but also from other sources such as fungi or dead cells may accumulate on high-touch surfaces. Taken together, we concluded that ATP is an unreliable measure for monitoring pathogenic bacteria on high-touch surfaces in hospitals.

Interestingly, the presence of S. aureus in the bacterial mixture promoted the survival of E. coli compared with E. coli alone. By contrast, cardiolipin, which is an effective factor promoting S. aureus survival in dry environments [28, 29], had no effect on supporting the survival of E. coli after drying, suggesting the presence of another mechanism independent of cardiolipin. Although this mechanism remains unknown, coexistence with cocci, which have a smaller surface area than bacilli and therefore retain water more effectively, may aid the survival of bacilli on dry surfaces. High-touch dry surfaces are invariably contaminated with S. aureus because this organism is a ubiquitous inhabitant of the human body, and it is therefore crucial to understand its dynamics on dry surfaces. Cardiolipin is a membrane component that enhances stress tolerance, thereby maintaining bacterial viability [4345], and several studies have shown that cardiolipin is involved in biofilm formation [46, 47]. We therefore assessed whether the presence of cardiolipin affected the survival of E. coli on dry surfaces, but no impact was detected indicating that other factors may be involved.

Although bacterial numbers dramatically reduced each day on dry surfaces, the degree of this reduction varied slightly between experiments and the degree to which S. aureus promoted the survival of E. coli also varied between experiments. This indicated that there may be factors other than temperature that regulate bacterial survival on dry fomites. Humidity, which can block water evaporation, has also been reported to have an impact on bacterial survival [3436, 48, 49]. Our experiments showed that constant humidity (40%–60%) affected the survival of bacteria on dry surfaces. Whereas, after prolonged incubation without humidity control (less than 20% humidity) (See Fig 1C), variation in bacterial numbers appeared to be increased, suggesting that low humidity can favor the survival of small numbers of bacteria on dry materials. However, because of the difficulties in controlling humidity, we did not accurately adjust humidity in our experiments. Therefore, further studies are needed in which humidity, as well as temperature, are more precisely controlled.

As expected, we confirmed that the warming handrail adjusted to body core temperature prohibited the prolonged survival of several nosocomial-related pathogens including E. coli, S. aureus, E. faecalis, P. aeruginosa, A. baumannii, S. marcescens and C. albicans. The heated handrail device used in this study was constructed using an acrylic board processing equipment kit (see Materials and methods), which cost 5,680 yen (JPY) (approximately $60). Because this device was cheap and simple to construct, involving a stainless steel handrail pipe (diameter, 13 mm; thickness, 2 mm) equipped with a heater wire in the center of the pipe to control the dry surface at body core temperature, we believe that this technology may be applicable for the development of heated handrails for use in hospitals to control hospital-acquired infections. One limitation of this device was that the temperature varied from the end to the center of the pipe (range: 30°C-40°C), meaning that the temperature on the device surface was not constant, as indicated by the differences in bacterial numbers spotted onto the agar plates from each of the samples collected from the handrail. Further improvements in the design of this device are therefore needed prior to practical use.

In conclusion, we demonstrated that human pathogens (E. coli, S. aureus, E. faecalis, P. aeruginosa, A. baumannii, S. marcescens and C. albicans), responsible for nosocomial infections. favor a lower temperature for their survival in dry environments. Based on this finding, we proposed a novel and simple strategy involving the warming of high-touch fomites in hospitals to body core temperature, to control the survival of human pathogenic bacteria responsible for nosocomial infections. However, this study had several limitations. As mentioned above, humidity, which can also influence bacterial survival, was not accurately controlled throughout our experiments [3436, 48, 49], and also the range of human pathogens used for this study were limited. Further studies are needed to clarify the effect of humidity on bacterial survival under dry conditions and to confirm the reproducibility of our findings in other bacteria. Further innovations are also needed to develop handrails or doorknobs with a uniform surface temperature equivalent to that of the core human body temperature before practical application in hospital environments.

Supporting information

S1 Fig [rlus]
ATP assessment of the bacterial spots on the vinyl chloride material showed that there were no significant differences corresponding to incubation times or temperature.

S2 Fig [pdf]
Cardiolipin had no effect on . survival after drying.

S3 Fig [pdf]
Effect of humidity on the survival of bacteria (. and . ) on dry environments (plastic).

S4 Fig [pdf]
Surface temperature on the handrail pipe with or without the heater.

S5 Fig [pdf]
Handrail device warmed to human body core temperature prohibited the prolonged survival of yeast-like fungus (. ).


Zdroje

1. Cobrado L, Silva-Dias A, Azevedo MM, Rodrigues AG. (2017) High-touch surfaces: microbial neighbours at hand. Eur J Clin Microbiol Infect Dis 36:2053–2062. doi: 10.1007/s10096-017-3042-4 28647859

2. Han JH, Sullivan N, Leas BF, Pegues DA, Kaczmarek JL, Umscheid CA. (2015) Cleaning Hospital Room Surfaces to Prevent Health Care-Associated Infections: A Technical Brief. Ann Intern Med 163:598–607. doi: 10.7326/M15-1192 26258903

3. Carling PC, Bartley JM. (2010) Evaluating hygienic cleaning in health care settings: what you do not know can harm your patients. Am J Infect Control 38(5 Suppl 1):S41–50. doi: 10.1016/j.ajic.2010.03.004 20569855

4. Rutala WA, Weber DJ. (2016) Monitoring and improving the effectiveness of surface cleaning and disinfection. Am J Infect Control 44(5 Suppl):e69–76. doi: 10.1016/j.ajic.2015.10.039 27131138

5. Donskey CJ. (2013) Does improving surface cleaning and disinfection reduce health care-associated infections? Am J Infect Control 41(5 Suppl):S12–19. doi: 10.1016/j.ajic.2012.12.010 23465603

6. Boyce JM. (2016) Modern technologies for improving cleaning and disinfection of environmental surfaces in hospitals. Antimicrob Resist Infect Control 5:10. doi: 10.1186/s13756-016-0111-x 27069623

7. Dancer SJ, White LF, Lamb J, Girvan EK, Robertson C. (2009) Measuring the effect of enhanced cleaning in a UK hospital: a prospective cross-over study. BMC Med 7:28. doi: 10.1186/1741-7015-7-28 19505316

8. Dancer SJ, White L, Robertson C. (2008) Monitoring environmental cleanliness on two surgical wards. Int J Environ Health Res 18:357–364. doi: 10.1080/09603120802102465 18821374

9. Dancer SJ. (2009) The role of environmental cleaning in the control of hospital-acquired infection. J Hosp Infect 73:378–385. doi: 10.1016/j.jhin.2009.03.030 19726106

10. Carling PC. (2016) Optimizing Health Care Environmental Hygiene. Infect Dis Clin North Am 30:639–660. doi: 10.1016/j.idc.2016.04.010 27515141

11. Anderson RE, Young V, Stewart M, Robertson C, Dancer SJ. (2011) Cleanliness audit of clinical surfaces and equipment: who cleans what? J Hosp Infect 78:178–181. doi: 10.1016/j.jhin.2011.01.030 21497943

12. Carling PC, Bartley JM. (2010) Evaluating hygienic cleaning in health care settings: what you do not know can harm your patients. Am J Infect Control 38(5 Suppl 1):S41–50. doi: 10.1016/j.ajic.2010.03.004 20569855

13. Park JW, Lee KJ, Lee KH, Lee SH, Cho JR, Mo JW, Choi SY, Kwon GY, Shin JY, Hong JY, Kim J, Yeon MY, Oh JS, Nam HS. (2017) Hospital Outbreaks of Middle East Respiratory Syndrome, Daejeon, South Korea, 2015. Emerg Infect Dis 23:898–905. doi: 10.3201/eid2306.160120 28516865

14. Ocampo W, Geransar R, Clayden N, Jones J, de Grood J, Joffe M, Taylor G, Missaghi B, Pearce C, Ghali W, Conly J. (2017) Environmental scan of infection prevention and control practices for containment of hospital-acquired infectious disease outbreaks in acute care hospital settings across Canada. Am J Infect Control 45:1116–1126. doi: 10.1016/j.ajic.2017.05.014 28732739

15. Hurford A, Lin AL, Wu J. (2015) Determinants of the Final Size and Case Rate of Nosocomial Outbreaks. PLoS One 10:e0138216. doi: 10.1371/journal.pone.0138216 26371880

16. Watanabe R, Shimoda T, Yano R, Hayashi Y, Nakamura S, Matsuo J, Yamaguchi H. (2014) Visualization of hospital cleanliness in three Japanese hospitals with a tendency toward long-term care. BMC Res Notes 7:121. doi: 10.1186/1756-0500-7-121 24593868

17. Shimoda T, Yano R, Nakamura S, Yoshida M, Matsuo J, Yoshimura S, Yamaguchi H. (2015) ATP bioluminescence values are significantly different depending upon material surface properties of the sampling location in hospitals. BMC Res Notes 8:807. doi: 10.1186/s13104-015-1757-9 26689425

18. Yano R, Shimoda T, Watanabe R, Kuroki Y, Okubo T, Nakamura S, Matsuo J, Yoshimura S, Yamaguchi H. (2017) Diversity changes of microbial communities into hospital surface environments. J Infect Chemother 23:439–445. doi: 10.1016/j.jiac.2017.03.016 28431935

19. Panagea S, Winstanley C, Walshaw MJ, Ledson MJ, Hart CA. (2005) Environmental contamination with an epidemic strain of Pseudomonas aeruginosa in a Liverpool cystic fibrosis centre, and study of its survival on dry surfaces. J Hosp Infect 59:102–107. doi: 10.1016/j.jhin.2004.09.018 15620443

20. Espinal P, Martí S, Vila J. (2012) Effect of biofilm formation on the survival of Acinetobacter baumannii on dry surfaces. J Hosp Infect 80:56–60. doi: 10.1016/j.jhin.2011.08.013 21975219

21. Warnes SL, Keevil CW. (2011) Mechanism of copper surface toxicity in vancomycin-resistant enterococci following wet or dry surface contact. Appl Environ Microbiol 77:6049–6059. doi: 10.1128/AEM.00597-11 21742916

22. Maudsdotter L, Imai S, Ohniwa RL, Saito S, Morikawa K. (2015) Staphylococcus aureus dry stress survivors have a heritable fitness advantage in subsequent dry exposure. Microbes Infect 17:456–461. doi: 10.1016/j.micinf.2015.02.004 25749710

23. Havill NL, Boyce JM, Otter JA. (2014) Extended survival of carbapenem-resistant Enterobacteriaceae on dry surfaces. Infect Control Hosp Epidemiol 35:445–447. doi: 10.1086/675606 24602956

24. Havill NL, Boyce JM, Otter JA. (2014) Extended survival of carbapenem-resistant Enterobacteriaceae on dry surfaces. Infect Control Hosp Epidemiol 35:445–447. doi: 10.1086/675606 24602956

25. Farhana I, Hossain ZZ, Tulsiani SM, Jensen PK, Begum A. (2016) Survival of Vibrio cholerae O1 on fomites. World J Microbiol Biotechnol 32:146. doi: 10.1007/s11274-016-2100-x 27430513

26. Okubo T, Matushita M, Ohara Y, Matsuo J, Oguri S, Fukumoto T, Hayasaka K, Akizawa K, Shibuya H, Shimizu C, Yamaguchi H. (2017) Ciliates promote the transfer of a plasmid encoding blaNDM-5 from Escherichia coli, isolated from a hospital in Japan, to other human pathogens. Int J Antimicrob Agents 49:387–388. doi: 10.1016/j.ijantimicag.2017.01.003 28167346

27. Okubo T, Matsushita M, Nakamura S, Matsuo J, Nagai H, Yamaguchi H. (2018) Acanthamoeba S13WT relies on its bacterial endosymbiont to backpack human pathogenic bacteria and resist Legionella infection on solid media. Environ Microbiol Rep 10:344–354. doi: 10.1111/1758-2229.12645 29611898

28. Maudsdotter L, Imai S, Ohniwa RL, Saito S, Morikawa K. (2015) Staphylococcus aureus dry stress survivors have a heritable fitness advantage in subsequent dry exposure. Microbes Infect 17:456–461. doi: 10.1016/j.micinf.2015.02.004 25749710

29. Beining PR, Huff E, Prescott B, Theodore TS. (1975) Characterization of the lipids of mesosomal vesicles and plasma membranes from Staphylococcus aureus. J Bacteriol 121:137–143. 1116984

30. Shannon RP. (2011) Eliminating hospital acquired infections: is it possible? Is it sustainable? Is it worth it? Trans Am Clin Climatol Assoc 122:103–114. 21686213

31. Farhangi MB, Safari Sinegani AA, Mosaddeghi MR, Unc A, Khodakaramian G. (2013) Impact of calcium carbonate and temperature on survival of Escherichia coli in soil. J Environ Manage 119:13–19. doi: 10.1016/j.jenvman.2013.01.022 23434791

32. Redfern J, Verran J. (2017) Effect of humidity and temperature on the survival of Listeria monocytogenes on surfaces. Lett Appl Microbiol 64:276–282. doi: 10.1111/lam.12714 28101930

33. Browne C, Loeffler A, Holt HR, Chang YM, Lloyd DH, Nevel A. (2017) Low temperature and dust favour in vitro survival of Mycoplasma hyopneumoniae: time to revisit indirect transmission in pig housing. Lett Appl Microbiol 64:2–7. doi: 10.1111/lam.12689 27759918

34. Esteves DC, Pereira VC, Souza JM, Keller R, Simões RD, Winkelstroter Eller LK, Rodrigues MV. (2016) Influence of biological fluids in bacterial viability on different hospital surfaces and fomites. Am J Infect Control 4:311–314.

35. Galvin S, Dolan A, Cahill O, Daniels S, Humphreys H. (2012) Microbial monitoring of the hospital environment: why and how? J Hosp Infect 82:143–151. doi: 10.1016/j.jhin.2012.06.015 23022372

36. Abreu AC, Tavares RR, Borges A, Mergulhão F, Simões M. (2013) Current and emergent strategies for disinfection of hospital environments. J Antimicrob Chemother 68:2718–2732. doi: 10.1093/jac/dkt281 23869049

37. Bergmann TWM, Kappers AM. (2008) Thermosensory reversal effect quantified. Acta Psychol (Amst) 127:46–50.

38. Moore G, Smyth D, Singleton J, Wilson P. (2010) The use of adenosine triphosphate bioluminescence to assess the efficacy of a modified cleaning program implemented within an intensive care setting. Am J Infect Control 38: 617–622. doi: 10.1016/j.ajic.2010.02.011 20605265

39. Boyce JM, Havill NL, Dumigan DG, Golebiewski M, Balogun O, Rizvani R. (2009) Monitoring the effectiveness of hospital cleaning practices by use of an adenosine triphosphate bioluminescence assay. Infect Control Hosp Epidemiol 30: 678–684. doi: 10.1086/598243 19489715

40. Andersen BM, Rasch M, Kvist J, Tollefsen T, Lukkassen R, Sandvik L, Welo A. (2009) Floor cleaning: effect on bacteria and organic materials in hospital rooms. J Hosp Infect 71: 57–65. doi: 10.1016/j.jhin.2008.09.014 19013671

41. Malik RE, Cooper RA, Griffith CJ. (2003) Use of audit tools to evaluate the efficacy of cleaning systems in hospitals. Am J Infect Control 31: 181–187. doi: 10.1067/mic.2003.34 12734526

42. Griffith CJ, Cooper RA, Gilmore J, Davies C, Lewis M. (2000) An evaluation of hospital cleaning regimes and standards. J Hosp Infect 45: 19–28. doi: 10.1053/jhin.1999.0717 10833340

43. Musatov A, Sedlák E. (2017) Role of cardiolipin in stability of integral membrane proteins. Biochimie 142:102–111. doi: 10.1016/j.biochi.2017.08.013 28842204

44. Maudsdotter L, Imai S, Ohniwa RL, Saito S, Morikawa K. (2015) Staphylococcus aureus dry stress survivors have a heritable fitness advantage in subsequent dry exposure. Microbes Infect 17:456–461. doi: 10.1016/j.micinf.2015.02.004 25749710

45. Xie Y, Yang L. (2016) Calcium and magnesium ions are membrane-active against stationary-phase Staphylococcus aureus with high specificity. Sci Rep 6:20628. doi: 10.1038/srep20628 26865182

46. Nepper JF, Lin YC, Weibel DB. (2019) Rcs Phosphorelay Activation in cardiolipin-deficient Escherichia coli reduces biofilm formation. J Bacteriol 201(9). pii: e00804-18.

47. Lin TY, Santos TM, Kontur WS, Donohue TJ, Weibel DB. (2015) A cardiolipin-deficient mutant of Rhodobacter sphaeroides has an altered cell shape and is impaired in biofilm formation. J Bacteriol 197:3446–3455. doi: 10.1128/JB.00420-15 26283770

48. Russotto V, Cortegiani A, Raineri SM, Giarratano A. (2105) Bacterial contamination of inanimate surfaces and equipment in the intensive care unit. J Intensive Care 3:54.

49. Wolkoff P. (2018) Indoor air humidity, air quality, and health—An overview. Int J Hyg Environ Health 221:376–390. doi: 10.1016/j.ijheh.2018.01.015 29398406


Článek vyšel v časopise

PLOS One


2019 Číslo 12
Nejčtenější tento týden
Nejčtenější v tomto čísle
Kurzy

Zvyšte si kvalifikaci online z pohodlí domova

Svět praktické medicíny 1/2024 (znalostní test z časopisu)
nový kurz

Koncepce osteologické péče pro gynekology a praktické lékaře
Autoři: MUDr. František Šenk

Sekvenční léčba schizofrenie
Autoři: MUDr. Jana Hořínková

Hypertenze a hypercholesterolémie – synergický efekt léčby
Autoři: prof. MUDr. Hana Rosolová, DrSc.

Význam metforminu pro „udržitelnou“ terapii diabetu
Autoři: prof. MUDr. Milan Kvapil, CSc., MBA

Všechny kurzy
Kurzy Podcasty Doporučená témata Časopisy
Přihlášení
Zapomenuté heslo

Zadejte e-mailovou adresu, se kterou jste vytvářel(a) účet, budou Vám na ni zaslány informace k nastavení nového hesla.

Přihlášení

Nemáte účet?  Registrujte se

#ADS_BOTTOM_SCRIPTS#