#PAGE_PARAMS# #ADS_HEAD_SCRIPTS# #MICRODATA#

The effects of isobaric and hyperbaric bupivacaine on maternal hemodynamic changes post spinal anesthesia for elective cesarean delivery: A prospective cohort study


Authors: Shamill Eanga Helill aff001;  Wossenyeleh Admasu Sahile aff002;  Ritbano Ahmed Abdo aff003;  Getahun Dendir Wolde aff004;  Hassen Mosa Halil aff003
Authors place of work: Department of Anesthesia,College of Medicine and Health Sciences,Wachemo University, Hossana, Ethiopia aff001;  Department of Anesthesia, School of Medicine, Addis Ababa University Addis, Addis Ababa, Ethiopia aff002;  Department of Midwifery,College of Medicine and Health Sciences,Wachemo University, Hossana, Ethiopia aff003;  Department of Anesthesia, School of Medicine, Wolaita Sodo University, Wolaita, Ethiopia aff004
Published in the journal: PLoS ONE 14(12)
Category: Research Article
doi: https://doi.org/10.1371/journal.pone.0226030

Summary

Background

Spinal anesthesia is a form of regional anesthesia frequently used in various lower abdominal, orthopedic, obstetric operations such as a cesarean delivery. The most common local anesthetic used for spinal anesthesia in obstetric and non-obstetric surgery is bupivacaine which can be utilized as an isobaric or hyperbaric solution, producing differences in maternal hemodynamic changes. Against this backdrop, the study aims to compare the effects of isobaric and hyperbaric bupivacaine on maternal hemodynamic alterations after administering spinal anesthesia for elective cesarean delivery at Gandhi Memorial Hospital, Addis Ababa, Ethiopia.

Methods

A hospital-based prospective cohort study design was employed for the period December 1, 2017 to January 30, 2018. A total of 100 parturient were involved, with one group exposed to isobaric bupivacaine and the other to hyperbaric bupivacaine to observe their effects on maternal hemodynamic changes post spinal anesthesia. The participants were selected through systematic random sampling. Data analysis was performed using SPSS (version 20) through descriptive statistic, independent sample t-test, Mann-Whitney U-test, Fisher’s exact test, and Chi-square test were used. P values of <0.05 was assumed as statistically significant for all tests.

Results

The incidence of hypotension was found to be greater in isobaric than hyperbaric groups (82% vs. 60% respectively; p = 0.015). No statistical significant differences were found in mean arterial pressure value at baseline, but, statistically significant changes were observed among the groups (p <0.05) at all study timing after spinal anesthesia, except at 30thmin. No statistically significant differences were seen in the mean heart rate variability after spinal anesthesia at all periods, except the 15th minute (p = 0.033). A greater rate of vasopressor was used in the isobaric group as compared to the hyperbaric group (36% vs. 14% respectively; p = 0.011).

Conclusion

Baricity is a significant factor in maternal hemodynamic changes in the parturient for elective cesarean section. Isobaric bupivacaine produces greater change in blood pressure and incidence of hypotension and entails a greater vasopressor requirement than hyperbaric bupivacaine after spinal anesthesia for elective cesarean section.

Keywords:

Obstetrics and gynecology – blood pressure – Hemodynamics – Data processing – Anesthesia – Local and regional anesthesia – cesarean section – Hypotension

Introduction

Spinal anesthesia (SA) is a form of regional anesthesia (RA) used frequently in various lower abdominal, orthopedic, and obstetric operations, including cesarean delivery (CD) [14]. The most common anesthetic used for SA in obstetric and non-obstetric surgery is bupivacaine, which can be formulated as an isobaric or hyperbaric solution [57].

Cesarean delivery is usually performed under SA using hyperbaric bupivacaine. This has been associated with an increased incidence of severe hypotension [8]. Isobaric bupivacaine is not commonly used for SA but can be a good alternative for obstetrics due to its lower maternal hemodynamic changes [9]. Besides the volume, concentration, and dose, the baricity of the solution can affect the spinal block profile [1013].

Baricity differences between spinal anesthetic solutions are thought to affect hemodynamic parameters and distribution within the subarachnoid space, which may, in turn, affect onset, extent, and duration of sensory block as well as side effects [14].

It is commonly believed that hyperbaric solutions are more suitable to reach the higher thoracic dermatomes as opposed to their plain equivalents [15]. The aim of all anesthesia professionals is to perform SA with the lowest deviation in blood pressure and heart rate, assuming that the patient is hemodynamically normal preoperatively. In doing so, RA of various baricity are used [16].

Hypotension is the most common effect of neuraxial anesthesia, mainly in obstetric surgery. The prevalence of hypotension in obstetric patients under SA, particularly in CDs, is 80–90% [8]. Hypotension causes unpleasant symptoms such as nausea and vomiting, bradycardia, unconsciousness, respiratory depression, and cardiac arrest in mothers who undergo CD. In severe and prolonged conditions, it leads to impairment of uterine perfusion and, ultimately, fetal acidosis and neonatal depression [17, 18].

Factors that increase the risk of hypotension include patient factors (advanced age, female sex, pregnancy, obesity, diabetes mellitus, hypertension, anemia) and technical factors such as a block level at or above T5, the baricity of the drugs, use of opioids as premedication, and high RA dosages [19, 20].

Published data shows that various measures have been taken to reduce spinal-induced hypotension in parturients undergoing elective CD, such as left-lateral tilt; IV fluid preloading or co-loading; leg elevation; and prophylactic use of vasopressors, but the incidence of hypotension is still high [21, 22]. Additional studies have been recommended to determine the relative effect of the baricity of regional anesthetics on spinal block characteristics, especially in parturients. To the best of our knowledge, there is no published research found in Ethiopia that shows the effects of isobaric and hyperbaric bupivacaine on maternal hemodynamic changes. Therefore, the study aims to compare the effects of isobaric and hyperbaric bupivacaine on maternal hemodynamic alterations after administering spinal anesthesia for elective cesarean delivery at Gandhi memorial hospital, Addis Ababa, Ethiopia.

Methods and materials

A hospital-based prospective cohort study design was employed for the period December 1, 2017 to January 30, 2018 at Gandhi memorial hospital. The source population consisted of pregnant mothers who underwent an elective CD during the study period. Study population consisted of selected pregnant mothers who underwent an elective CD during the study period. The inclusion criteria were: all women underwent an elective caesarean delivery during the study period. On the other, mothers with systemic and psychological disorders, mother with the pregnancy complications, emergency CD, failed spinal block, any contraindications for spinal anesthesia and allergy to RA were excluded from the study.

Pregnant mothers who underwent an elective CD with isobaric comprised the exposed group and those who underwent with Hyperbaric Bupivacaine comprised the unexposed group. The sample size was computed by using the double population proportion formula. The following assumptions were used to estimate the sample size; the incidence of hypotension was taken from the preliminary data from Iran (42% in the unexposed group and 70% in the exposed group) [23], with a 95% confidence interval, a 5% desired precision and 80% power, the sample size was 100 (50 per group). A systematic random sampling method was used to select study participants from each group. From all scheduled parturient who fulfilled the inclusion criteria to undergo caesarean section on the operation list, the samples were selected skipping every 2 interval. The first parturient was selected by a lottery method from the first two schedules. Based on the decision of anaesthetists, the selected parturient were placed in either group until the required sample size was filled.

Data were collected using pretested structured questionnaires. Anaesthetists, two with bachelor’s degree and one with a master’s degree, were hired for the data collection and supervision. Preoperative evaluation was done a day before operation to keep NPO, to fulfil necessary investigations based on historical findings, and to perform a physical examination via hospital anaesthetists. The functionality of the operation room equipment was checked and prepared with the necessary drugs early in the morning. Before the parturient entered the operation room, a chart review including socio-demographic identification, maternal characteristics, and indication for CD was identified by on-duty anaesthetists assigned per hospital programme. All parturient were preloaded with 0.9% NS 10–20 ml/kg. Premedication ceftriaxone 1gm and metoclopramide 10 mg IV were given upon arrival in the waiting area for the operation room.

The operation room routine included standard monitoring with non-invasive blood pressure, electrocardiogram (ECG), and pulse oxymetry monitoring. The baseline blood pressure and heart rate were measured five minutes before administration of the spinal anaesthesia. Under all aseptic conditions, spinal anaesthesia was instituted in the sitting position using the anterior superior iliac crest as a surface landmark with a 25-G pencil-point spinal needle at L3-4 inter-space level. After the correct needle placement, as identified by the free flow of CSF, 12.5mg of bupivacaine was given over a period of ten seconds.

Immediately after the spinal injection, the parturients were gently assisted to lie in supine position kept at 150 left uterine displacement. Patients were followed for 30 minutes after SA administration. Data collectors recorded vital signs every 5 minutes throughout the surgery and success of spinal anesthesia was assessed by sympathetic block, reduction in motor function. The level of sensory blockade was assessed by applying iced gauzes on the mother’s skin and documented. Parturients who developed hypotension and not enabled to correct with fluid and position, ephedrine 5mg IV bolus were used for treatment of hypotension. Hypotension: In this study, hypotension was defined as a 25% decrease in systolic blood pressure from pre-anesthetic value after the spinal anesthesia administration.

The quality of data maintained through, a questionnaires was pre-tested on 5% of the sample size at black lion specialized hospital, and necessary modifications were made based on the nature of gaps identified in the questionnaire. Additionally, data collectors and supervisors were oriented for a day by the investigators on the content of the questionnaire. Moreover, the supervisors and the investigators closely followed the day-to-day data collection process during the pretest and the actual data collection.

Data processing and analysis

Data were entered and analysed using SPSS version 20.0. Descriptive statistics (i.e., frequency, percentage, median, mean, and standard deviation) were applied to describe the pattern of the data. Furthermore, the normality of the quantitative data was evaluated using the Shapiro-Wilk and Kolmogrove-Smirnov test, and the homogeneity by the Levanes test of equality of variance. Independent samples t-test, Mann-Whitney U-test, chi-square test and Fisher’s exact test were used. P values of <0.05 were assumed as statistically significant for all tests.

Ethics approval and consent to participate

The ethical clearance letter was obtained from Institutional Review Board of Addis Ababa University, department of anesthesia research ethical committee. Additionally, permission was obtained from the Gandhi memorial hospital administration. Finally, written informed consent was obtained from each participant, which has been included in the study during the data collection time, after explaining the objectives of the study to them. Furthermore, confidentiality was maintained through not asking personal identifiers like name and address.

Results

Demographic, perioperative characteristics of parturients

A total of 100 women who had undergone CD were included in the study. Within this group, 50 parturients took isobaric and 50 parturients took hyperbaric. No statistically significant differences were observed among the groups with respect to age, weight, height, BMI, ASA status, parity, gestational age, indication for CD, sensory block level, amount of fluids used, amount of blood loss, baseline SBP and baseline HR. A majority of parturients had undergone an elective cesarean with an indication of previous CD (56% in the hyperbaric and 62% in the isobaric groups) (Table 1).

Tab. 1. Demographic data, perioperative variables among groups at Gandhi Memorial Hospital, Addis Ababa, Ethiopia, 2018.
Demographic data, perioperative variables among groups at Gandhi Memorial Hospital, Addis Ababa, Ethiopia, 2018.

Hemodynamic characteristics of parturients

The incidence of systolic hypotension after the administration of spinal anesthesia was 62% [95% CI, 46%–74%] in the hyperbaric group and 82% in the isobaric group with X2 = 5.90. Statistically significant differences were observed between the groups (p = 0.015). While a greater incidence of hypotension was seen in the isobaric than in the hyperbaric group, there were no statistical differences in mean MAP value at baseline. After spinal anesthesia was administered, statistically significant changes were observed among the groups (p < 0.05) during all the study timings except at the 30th minute. Decreased MAP was more prevalent in the isobaric than the hyperbaric group from the 5th to the 25th minutes (S1 Fig).

No statistically significant differences was observed in the mean HR variability after the administration of spinal anesthesia at all the study periods between the groups, except at the 15th minute. A significantly greater heart rate variability was recorded in the isobaric group at the 15th minute than the hyperbaric group after the administration of spinal anesthesia as compared to the baseline values (p = 0.033). Since none of the clients developed bradycardia, no supplementary atropine was required (Table 2).

Tab. 2. Change in HR in first 30 minute among groups at Gandhi Memorial Hospital, Addis Ababa, Ethiopia, 2018.
Change in HR in first 30 minute among groups at Gandhi Memorial Hospital, Addis Ababa, Ethiopia, 2018.

The effect of isobaric and hyperbaric bupivacaine on the level of sensory blockage

The levels of sensory block among the groups were observed, and a majority of the clients had T8 sensory block level in the hyperbaric group (64%) and T6 sensory block level in the isobaric group (62%). A sensory block level of T4 and above was observed in 3 clients from the isobaric group (6%) and none in the hyperbaric group. T10 sensory blockage level was observed in 6% of the isobaric and in 2% of the hyperbaric groups. There were statistically significant differences in the level of sensory blockage among groups (p = 0.001) (S2 Fig).

Rate of vasopressor consumption between the groups and intra-operative maternal complications

The rate of ephedrine requirement was relatively greater in the isobaric group 18 (36%) than the hyperbaric group 7 (14%) for the treatment of hypotension and it is statistically significant (p = 0.011). Nausea and vomiting were the most common maternal complications, which accounted for 44% in isobaric and 20% in hyperbaric groups of all complications. Relatively higher maternal complications were observed in with respect to nausea and vomiting, light headedness and respiratory depression in isobaric group. It was statistically significant between the groups (p = 0.001).

Discussion

In this study, the incidence of hypotension was found to be greater in the isobaric than in the hyperbaric group (82% vs. 60%; p = 0.015). Statistically significant differences were observed between groups. Similar findings were also reported in a study done in Pakistan [24], and Turk [25]. In contrast, this study found a higher incidence of hypotension in isobaric than in hyperbaric groups compared to studies carried out in, Iran [23], United Kingdom [26], and Wales [27]. These differences might be due to difference in position, block height, spine curvature, socio-demographic characteristics and experiences of anesthetists.

There was no statistical significant differences in mean MAP value at baseline, but after spinal anesthesia statistically significant changes were observed between the groups at all study timing, except at 30th minute. Decreased MAP in this study was observed more in isobaric than in hyperbaric groups from 5 to 25 minutes. In contrast, other studies conducted in Bosnia and Herzegovina[7] and Wales [27] revealed a greater reduction in MAP in hyperbaric than in isobaric groups. These differences might be due to the position and height of parturient, volume of local anesthetics used, the possibility of dehydration, and the amount of vasoactive drugs used.

In addition, a significantly higher heart rate (HR) variability was recorded in the isobaric group at the 15th minute than in the hyperbaric group with respect to baseline values. This finding is in contrast with a study conducted in Indonesia [28] that reported no significant differences in the HR variability between groups. On the other hand, our result is inconsistent with a study done in Bosnia and Herzegovina [7] that reported pulse frequency decreased significantly in hyperbaric groups in comparison to isobaric groups.This difference might be due to blockage of sympathetic accelerator fibers and high level of sensory blockage.

This study revealed a higher level of sensory blockage in the isobaric groups. This is supported by researches done in Indonesia [28]. This was in contrast to what was observed in Iran[23] which showed a lower sensory block level in isobaric groups. The observed difference might have been due to the fact that adopting supine position, even with left lateral tilt, causes inferior vena cava compression, which in turn results in an engorgement of the epidural venous plexus. The consequent dural sac compression may facilitate bulk movement of drugs injected into the CSF and could explain the cephalad progression of the isobaric bupivacaine.

In this study, a greater rate of ephedrine was required in isobaric groups. However, in contrast to what was found in Wales [27] and Iran [23], an ephedrine requirement was not found to be greater in the hyperbaric group in this study.

Nausea and vomiting were the most common maternal complications, which accounted for 44% in isobaric and 20% in hyperbaric groups of all complications. The occurrence of nausea and vomiting might be secondary to hypotension, which was effectively reversed with fluid administration and ephedrine as a vasopressor. In contrast to our result, studies done in the United Kingdom and Pakistan found insignificant differences in the incidence of nausea and vomiting [10, 24]. This might be due to difference in the incidence of hypotension, vagal hyperactivity, visceral pain, utero-tonic agents, and sympathectomy.

Strength of the study: Study participants were selected using probability sampling method to ensure its representatives and different approaches were used to maintain the quality of data. No loss of parturients that resulted in missing data to follow up on. Limitations of the study are the inaccessibility of invasive arterial blood pressure to measure parturient beat-to-beat systolic blood pressure. The onset and duration of sensory and motor blockage was not evaluated. The duration of hypotension could not be measured with every hypotensive episode due to noninvasive monitoring device is adjusted every 5 minutes in the hospital.

Conclusion

Baricity is a significant factor in maternal hemodynamic changes in the parturient for elective cesarean section. Isobaric bupivacaine produces a greater change in blood pressure and incidence of hypotension and entails a higher vasopressor requirement than hyperbaric bupivacaine after spinal anesthesia for elective cesarean section.

Supporting information

S1 Fig [tif]
Change in mean MAP in first 30 minute after spinal anesthesia among groups at Gandhi Memorial Hospital, Addis Ababa, Ethiopia, 2018.

S2 Fig [tif]
Level of sensory block after spinal anesthesia among groups at Gandhi Memorial Hospital, Addis Ababa, Ethiopia, 2018.

S1 File [docx]
Consent form and questionnaire.

S2 File [sav]
SPSS.


Zdroje

1. Wong JO, Tan TD, Leung P, Tseng K, Cheu N. Comparison of the effect of two differentdoses of 0.75% glucose-free ropivacaine forspinal anesthesia for lower limb and lower abdominal surgery. Kaohsiung J Med Sci 2004 20 9.

2. Urmey WF. Spinal anaesthesia for outpatient surgery. Best Pract Res Clin Anaesthesiol 2003;17:335–46. doi: 10.1016/s1521-6896(03)00015-6 14529006

3. Iohom BDODG. Regional anesthesia techniques for ambulatory orthopedic surgery. doi: 10.1097/aco.0b013e328314b665 19009687. 2008;21(6):723–8.

4. Stamer UM, Stüber F, Wulf H, Meuser T. Change in anaesthetic practice for Caesarean section in Germany. Acta Anaesthesiol Scand. 2005 49(2):170–6. doi: 10.1111/j.1399-6576.2004.00583.x 15715617

5. Birnbach DJ. Anesthesia for obstetrics. In: Miller RD, editor. Miller’s anesthesia.Philadelphia: Churchill Livingstone;. European Journal of Anaesthesiology (EJA). 2010.;31 (188):2203–40.

6. Chestnut D, Wong C, Tsen L, Beilin Y, Mhyre J. Chestnut’s obstetric anesthesia: Principles and practice. Philadelphia:ELSCIER. 2009:4th ed.

7. Solakovic N. Comparison of Hemodynamic Effects ofHyperbaric and Isobaric Bupivacaine in SpinalAnesthesia. MED ARH. 2010; 64(1):11–4 20422816

8. Ayorinde BT, Buczkowski P, Brown J, Shah J, Buggy DJ. Evaluation of pre-emptive intramuscular phenylephrine and ephedrine for reduction of spinal anaesthesia-induced hypotension during Caesarean section. Br J Anaesth. 2001; 86:372–6. doi: 10.1093/bja/86.3.372 11573527

9. Hussain MD, Mallick MT. Effects of isobaric bupivacaine in endoscopic urological surgeries under spinal anaesthesia. JAFMC Bangladesh. 2011; 7:33–6.

10. Loubert CF, Hallworth S, Fernando R, Columb MF, Patel N, Sarang K, et al. Does the Baricity of Bupivacaine Influence IntrathecalSpread in the Prolonged Sitting Position BeforeElective Cesarean Delivery?. A Prospective Randomized Controlled Study. www.anesthesia-analgesia.org. 2011 113 4. doi: 10.1213/ANE.0b013e3182288bf2 21890887

11. Danelli G, Di Cianni S, ZasaM md, De Marco G, Adamanti S. Effects of baricity of 0.5% or 0.75%levobupivacaine on the onset time of spinalanesthesia: a randomized trial. AN J ANESTH 2008;55: 8.

12. Malinovsky J-M, Renaud G, Corre PL, Pharm D, Charles FS, Malinge M, et al. Intratbecal Bupiuacaine in HumansInfluence of Volume and Baricity of Solutions. Anesthesiology. 1999;9I(1260–6).

13. Wason R. Comparison of hypobaric, near isobaric andhyperbaric bupivacaine for spinal anaesthesiain patients undergoing knee arthroscopy. wason, gogia,. ahni;rupa:445–8: comp.

14. Richardson MG, Wissler RN. Intrathecal hypobaric versus hyperbaric bupivacaine with morphine for cesarean section. Anesth Analg 1998;87: 336–40. doi: 10.1097/00000539-199808000-00019 9706927

15. Bigler D MI, Hjortso N-C. Double-blind evaluation of intrathecal hyperbaric and glucose-free bupivacaine on analgesia and cardiovascular function. Reg Anesth 1986;11:151–5.

16. Ehrenfeld JM, Urman RD. Segal S Anesthesia Student Survival Guide. A Case-Based Approach. Switzerland: Springer International Publishing 2016:2nd ed. doi: 10.1007/978-3-319-11083-7

17. Naz F, Begum A, Malik M, Zareen A. Complication of Spinal Anaesthesia in Caesarean Section. Pakistan Journal of Medical and Health Sciences 2010;4:3.

18. Singh M, Shamsah M. Influence of injection rate of hyperbaric bupivacaine on spinal block in parturients: a randomizedtrial. CAN J ANESTH. 2007 54 (4):290–5. doi: 10.1007/BF03022774 17400981

19. Brenck F, Katzer C, Obaid R, Brüggmann D, Benson M, Röhrig R, Junger A. Hypotension after spinal anesthesia for cesarean section: identifcation of risk factors using an anesthesia information management system. Journal of clinical monitoring and computing 2009;23:85–92. doi: 10.1007/s10877-009-9168-x 19277879

20. Hartmann B, Klasen J, Benson M, Jost A, Banzhaf A, Hempelmann G. The incidence and risk factors for hypotension after spinal anesthesia induction: an analysis with automated data collection. Anesth Analg 2002;94: 1521–9. doi: 10.1097/00000539-200206000-00027 12032019

21. Atef K. Salama HMG, Bassant M. Abdel Hamid. Fluid preloading versus ephedrine in the management of spinalanesthesia-induced hypotension in parturients undergoingcesarean delivery: a comparative study. Ain-Shams Journal of Anesthesiology 2016; 9:72–5.

22. Siddik-Sayyid SMM, Viviane G, Samar, Zbeide RAMS K., Jules-Marie A. Alami Al, et al. A Randomized Trial Comparing Colloid Preload to Coload During Spinal Anesthesia for Elective CesareanDelivery. October 2009 109 (4):1219–24. doi: 10.1213/ane.0b013e3181b2bd6b 19641050

23. Atashkhoei SM, Abedini NM, Pourfathi HM, Bahrami AZ, Hatami PM. Baricity of Bupivacaine on Maternal Hemodynamics after Spinal Anesthesia for Cesarean Section: A Randomized Controlled Trial. Iran J Med Sci. 2017;42: 2.

24. Aftab HA S., Zafar S.et.al. intrathecal isobaric versus hyperbaric bupivacaine for ellective cesarean section. Pakistan journal of Surgery. 2007;23(4).

25. Toptaş M, Uzman S, İşitemiz İ, Yanaral TU, Akkoç İ, Bican G. A comparison of the effects of hyperbaric and isobaric bupivacaine spinal anesthesia on hemodynamics and heart rate variability. Turkish Journal of Medical Sciences 2014; 44: 224–231. doi: 10.3906/sag-1207-1 25566589

26. Hallworth S, Roshan F, Columb MO. The Effect of Posture and Baricity on the Spread of Intrathecal Bupivacaine for Elective Cesarean Delivery. Obstetric Anesthesia: Research Report. 2005; 100 (4): 1159–65.

27. Critchley LA, Derrick J. The influence of baricity on the haemodynamic effects of intrathecal bupivacaine 0.5%. 1999;54:469–74. doi: 10.1046/j.1365-2044.1999.00841.x 10995146

28. Helmi M, Uyun Y, Suwondo BS, and Widodo U. Comparison of intrathecal use of isobaric and hyperbaric bupivacaine during lower abdomen surgery. J Anesthesiol 2014. 2014:1–4.


Článek vyšel v časopise

PLOS One


2019 Číslo 12
Nejčtenější tento týden
Nejčtenější v tomto čísle
Kurzy Podcasty Doporučená témata Časopisy
Přihlášení
Zapomenuté heslo

Zadejte e-mailovou adresu, se kterou jste vytvářel(a) účet, budou Vám na ni zaslány informace k nastavení nového hesla.

Přihlášení

Nemáte účet?  Registrujte se

#ADS_BOTTOM_SCRIPTS#