#PAGE_PARAMS# #ADS_HEAD_SCRIPTS# #MICRODATA#

An enhanced nonparametric EWMA sign control chart using sequential mechanism


Authors: Muhammad Riaz aff001;  Muhammad Abid aff002;  Hafiz Zafar Nazir aff003;  Saddam Akber Abbasi aff004
Authors place of work: Department of Mathematics and Statistics, King Fahad University of Petroleum and Minerals, Dhahran, Saudi Arabia aff001;  Department of Statistics Government College University Faisalabad, Pakistan aff002;  Department of Statistics University of Sargodha, Sargodha, Pakistan aff003;  Department of Mathematics, Statistics and Physics, Qatar University, Doha, Qatar aff004
Published in the journal: PLoS ONE 14(11)
Category: Research Article
doi: https://doi.org/10.1371/journal.pone.0225330

Summary

Control charts play a significant role to monitor the performance of a process. Nonparametric control charts are helpful when the probability model of the process output is not known. In such cases, the sampling mechanism becomes very important for picking a suitable sample for process monitoring. This study proposes a nonparametric arcsine exponentially weighted moving average sign chart by using an efficient scheme, namely, sequential sampling scheme. The proposal intends to enhance the detection ability of the arcsine exponentially weighted moving average sign chart, particularly for the detection of small shifts. The performance of the proposal is assessed, and compared with its counterparts, by using some popular run length properties including average, median and standard deviation run lengths. The proposed chart shows efficient shift detection ability as compared to the other charts, considered in this study. A real-life application based on the smartphone accelerometer data-set, for the implementation of the proposed scheme, is also presented.

Keywords:

Normal distribution – Accelerometers – Charts – Cell phones – Statistical distributions – quality control – Seismic signal processing

1. Introduction

Statistical process control (SPC) is a collection of tools for the monitoring of process parameters. The most valuable of these tools is control chart (cf. Montgomery [1]). Shewhart, cumulative sum (CUSUM) and exponentially weighted moving average (EWMA) charts (cf. [24]) are the commonly used control chart structures to monitor the parameters of the process. The simplicity and ease of interpretation make Shewhart charts more common in use, but they are relatively insensitive to small shifts in process parameters, whereas, CUSUM and EWMA control charts are mostly used for the detection of smaller shifts in process parameters (cf. [1]).

In parametric control charts, the parent distribution of the process production is usually known and commonly assumed to be a normal. If the distribution of the process production is unknown, the traditional control limits no longer remain effective and the detection ability of parametric control charts can be negatively affected. This leads us to the development of control charts that are not specifically designed under the assumption of normality or any other parametric distribution. In SPC literature, the nonparametric control charts are widely employed and have numerous advantages for the monitoring of real processes (cf. Chakraborti et al. [5]). For recent literature on nonparametric charts, the interested readers may go through the contributions by [614].

In SPC literature, various sampling techniques are used to improve the performance of the parametric and nonparametric control charts. Of these, simple random sampling (SRS), (cf. Montgomery [1]), double sampling (DS) (cf. Croasdale [15]), ranked set sampling (RSS) and its different forms (cf. [1617]), repetitive sampling (RS) (cf. [1819]) and variable sampling interval (VSI) (cf. [2021]) are famous ones. Balamurali and Jun [22] showed that the RS scheme is more efficient than single and double sampling schemes but it is not better than the sequential sampling (SS) scheme. The SS was introduced by Wald [23] as a tool for more effective industrial quality control during second world war. The SS is a sampling plan in which an undetermined number of samples are tested one by one, accumulating the results, until a decision can be made. In SS the sample size i.e., n is not fixed in advanced. Balamurali and Jun [22] mentioned that the SS is more efficient as compared to DS procedure. The SS and RS schemes are quite similar to each other. Both sampling schemes have a similar pair of limits and decision criteria is same for both designs. The only difference exists between these two designs when a sample falls in the no-decision interval. In RS, the sampler discards the sample that falls in the no-decision interval and the resampling will continue until a decision is reached. On the other hand, in SS, the sampler doesn’t ignore the sample that falls in the no-decision interval, the sampler draws a new sample and update the information with previous sample, until sample statistic falls in either of the decisive zones.

By exploring the literature, we found that no study as of yet, utilizes the SS scheme for increasing the efficiency of the nonparametric control charts. To fill this gap, we propose a nonparametric EWMA sign chart, based on arcsine transformation, using the SS scheme, for efficient monitoring of process location. The rest of the article is as follows: the description of the existing and proposed charts is presented in Section 2. The performance comparisons are provided in Section 3. A real application of the proposed chart is given in Section 4. Finally, the summary and conclusions are provided in Section 5.

2. Description of nonparametric control charts

In this section, we provide a brief description of some useful non-parametric charts such as: the nonparametric EWMA sign (EWMA-Sign), the arcsine EWMA (AEWMA-Sign) charts, proposed by Yang et al. [24], and the nonparametric CUSUM sign (CUSUM-Sign) chart proposed by Yang and Cheng [25].

2.1. EWMA-Sign chart

Let X be the variable of interest with mean value θ and T = Xθ defines the respective deviations from its mean value. Let p denote the proportion of positive deviations i.e. p = P(T>0). For in-control process, p = 0.5 and for out-of-control process, p = p1≠0.5. The sign test statistic is written as:


where I(.)is given as:

where j = 1,2,…,n.

Koti and Babu [26] showed that T+ follows the binomial distribution with parameters n and p. Moreover, E(T+) = n/2 and Var(T+) = n/4, respectively. The EWMA statistic based on (1) is written as:


where λ is the smoothing parameter ranging from 0 to 1.

Yang et al. [24] proposed the EWMA-Sign chart to monitor the process target. The mean and variance of the EWMA statistic in (2) are respectively given as (Abbasi [27] and Yang et al. [24]):


The asymptotic control limits of Yang et al. [24] chart are




where L is the width of the control limits.

2.2. AEWMA-Sign chart

Yang et al. [24] observed that due to the asymmetric behavior of the binomial distribution for small to moderate sample size n, the in-control average run length (ARL0) values of the EWMA sign chart are not equal to the usually known value of 370 when p = 0.5. So to overcome this deficiency, Yang et al. [24] applied the arcsine transformation i.e., T=sin−1(p). The distribution of T under the arcsine transformation follows the normal distribution with mean sin−1(p) and variance (14n). The EWMA statistic based on the arcsine transformation is defined as:


The starting value of EWMATi is set as the mean value of T as EWMAT0=sin−1(0.5). The mean and variance of the EWMATi are E(EWMATi)=sin−1(0.5) and Var(EWMATi)=λ2−λ(14n), respectively (cf. Yang et al. [24]).

So, the control limits of the arcsine EWMA sign chart are:




where p = 0.5 represents the in-control state of the process. If any EWMAT≥UCLEWMAT or EWMAT≤LCLEWMAT, the process is considered to be out-of-control. The AEWMA-Sign chart shows slightly better shift detection ability as compared to the EWMA-Sign chart (cf. Yang et al. [24]).

2.3. CUSUM-Sign chart

Using the statistic given in (1), Yang and Cheng [25] developed the two plotting statistic i.e., Ct+ and Ct− of the CUSUM sign chart as follows:


where t = 1,2,… and initially, Ct+=0 and Ct−=0. The statistics given in (6) are plotted against their control limits h and −h, respectively. The process is considered to be out-of-control if Ct+≥h or Ct−≤−h, else, it is in-control. For k = 0.5, h = 10.65 and n = 10, the ARL0 of the CUSUM−Sign chart is 370.

2.4. Proposed arcsine EWMA sign chart

In this section, we combine the idea of SS scheme with the nonparametric arcsine EWMA sign chart, namely the SAEWMA-Sign chart. The SS scheme is more economical and time-saving in comparison to the RS and DS schemes. In SS scheme undetermined number of samples are tested one by one, adding the results until a decision can be made. The construction of the SAEWMA-Sign chart is based on the following two steps:

Step I: A sample of size n is selected for the computation of the EWMA statistics, using the expression given in (4).

Step II: The SAEWMA-Sign chart has two pairs of control limits which consist of two upper control limits i.e., UCL1 and UCL2 and two lower control limits i.e., LCL1 and LCL2. The four control limits of the proposed chart, based on SS scheme are given as follows (cf. Aslam et al. [19]):


In (7), L1 and L2 (L1L2) are the two control limits coefficients to be determined.

The decision criteria of SAEWMA-Sign chart is outlined as:

  • the process is stated as out-of-control if EWMATi≥UCL1 or EWMATi≤LCL1;

  • if LCL2≤EWMATi≤UCL2 the process is declared to be in-control;

  • if LCL1≤EWMATi≤LCL2 or UCL2≤EWMATi≤UCL1 then continue sampling and go to step I (cf. Fig 1).

Decision criteria of the proposed chart (A model display).
Fig. 1. Decision criteria of the proposed chart (A model display).

Special Case: If L1 = L2, then the proposed scheme is similar to the AEWMA-Sign chart under the SRS scheme. So, the proposed chart is a special case of the chart proposed by Yang et al. [24].

3. Performance assessment

There are a variety of measures that can be used to evaluate the performance of control charts. Some of the important measures, used in this study are:

Average run length (ARL) is broadly used by the researchers to assess the performance of control charts. The in-control and out-of-control ARLs are denoted by ARL0 and ARL1, respectively. Some researchers recommend the use of standard deviation run length (SDRL) and median run length (MDRL), due to the skewed behavior of the run length (RL) distribution.

The ARL, MDRL and SDRL are defined as:




We have adopted Monte Carlo (MC) simulations based on 5×104 iterations to find the results. The advantages of MC simulation over the other methods can be seen in Dyer [28].

The computational algorithms for the computation of different run length measures is described below: described below:

  • Generate a random sample of size n from the binomial distribution, having parameters n and p = p0 = 0.5, call it Ti.

  • Compute the EWMATi statistics using the expression given in (4).

  • For a fixed level of λ, select values for L1 and L2 for the computation of control limits in (6), for a pre-specified ARL0.

  • The sample number at which the plotting statistic falls outside the UCL1 or LCL1 is called a run length. If LCL1≤EWMATi≤LCL2 or UCL2≤EWMATi≤UCL1, we continue resampling and repeat steps (i)–(iii) unless the plotting statistics falls in either of the decisive zones.

  • Repeat steps (i)-(v) 5×104 times to compute the in-control ARL as the mean of these run lengths.

For the out-of-control ARL, shifts are introduced by generating random observations from Binomial distribution using parameters n and p = p1≠0.5. To evaluate the performance of the proposed chart, we chose various combination of L1, L2, n and λ, to achieve a pre-specified ARL0. It is to be mentioned that the design parameter L2 is obtained by using the formula L2 = Lφ*L where L is defined earlier in Section 2 and φ helps in defining the non-decisive zone. For our study purpose, we used λ = 0.05 and 0.25 for the proposed chart and found the control chart multipliers L1 and L2 for fixing ARL0 = 370. Moreover, we have used φ = 0.02(0.02)0.1 in this study.

For these design parameters, we have obtained the run length properties of the proposed chart such as ARL, MDRL and SDRL. These results are provided in Table 1. From Table 1, we advocate the following interesting points:

  • The ARL0 values are close to the desired value of 370 when the value of p = 0.5 (for example for λ = 0.05,L1 = 2.665,L2 = 2.619,φ = 0.02,ARL0 = 369 and for λ = 0.25, L1 = 3.271,L2 = 3.155,φ = 0.02, ARL0 = 370).

  • It is noted that the efficiency of the proposed chart to detect small shifts in the process location, increases as the value of λ decreases (for example for λ = 0.25,L1 = 3.362,L2 = 3.090,φ = 0.04,p1 = 0.51, ARL1 = 303 and for λ = 0.05, L1 = 2.667,L2 = 2.565,φ = 0.04,p1 = 0.51,ARL1 = 257).

  • It is observed that the shift detection ability of the proposed scheme increases as the value of φ increase (for example for λ = 0.05, L1 = 2.665,L2 = 2.619,p1 = 0.51,φ = 0.02,ARL1 = 272 and for λ = 0.05, L1 = 2.665,L2 = 2.619,p1 = 0.51,φ = 0.08, ARL1 = 228).

  • The values of MDRL and SDRL decreases as the value of φ increases (for example for λ = 0.05,p1 = 0.52,φ = 0.02, MDRL = 120, SDRL = 150, and for λ = 0.05, p1 = 0.52, φ = 0.1,MDRL = 93,SDRL = 112).

  • The MDRL and SDRL also decreases with an increase in the level of p1, considering fixed λ and φ.

Tab. 1. Run length properties of the proposed chart under ARL0≈370.
Run length properties of the proposed chart under <i>ARL</i><sub>0</sub>≈370.

To get more insight of the run length distribution for the proposed chart, we also computed the run length properties at varying levels of n and λ. As the value of the n increases, the detection ability of the proposed chart increases. For example, for n = 10,p1 = 0.55,ARL1 = 42 and n = 15, p1 = 0.55,ARL1 = 31 (cf. Table 2 and Fig 2). On the other hand, as the value of λ increases the shift detection ability of the proposed chart decreases. For example, for λ = 0.05,p1 = 0.6,ARL1 = 17 and λ = 0.5, p1 = 0.6,ARL1 = 35 (cf. Table 3 and Fig 3).

<i>ARL</i> comparison of the proposed chart for different levels of <i>n</i> when <i>λ</i> = 0.05 and <i>φ</i> = 0.1.
Fig. 2. ARL comparison of the proposed chart for different levels of n when λ = 0.05 and φ = 0.1.
<i>ARL</i> comparison of the proposed chart for different levels of <i>λ</i> when <i>n</i> = 10 and <i>φ</i> = 0.1.
Fig. 3. ARL comparison of the proposed chart for different levels of λ when n = 10 and φ = 0.1.
Tab. 2. Run length properties of the proposed chart for different levels of n when λ = 0.05 and φ = 0.1.
Run length properties of the proposed chart for different levels of <i>n</i> when <i>λ</i> = 0.05 and <i>φ</i> = 0.1.
Tab. 3. Run length properties of the proposed chart for different levels of λ when n = 10 and φ = 0.1.
Run length properties of the proposed chart for different levels of <i>λ</i> when <i>n</i> = 10 and <i>φ</i> = 0.1.

3.1. Comparative analysis

In this section, we present a comparison of the proposed scheme with the EWMA-Sign chart, the AEWMA-Sign chart and the CUSUM-Sign chart. To make valid comparisons with existing counterparts, ARL0 of all selected charts is fixed at a pre-specified level i.e., ARL0 = 370.

3.1.1. Proposed Vs EWMA-Sign

The ARL values of the EWMA-Sign chart and proposed SAEWMA-sign chart are presented in Table 4, under different shift levels. The comparison reveals that SAEWMA-Sign chart performs efficiently at different shift levels (for example, with n = 10, p1 = 0.51,0.53,0.55 and 0.7, the ARL values of the proposed SAEWMA-Sign chart are ARL1 = 214,82,42,7 whereas the corresponding ARL1 = 288,106,52,8 for EWMA-Sign chart (cf. Table 4)). From Table 4, it is revealed that for all the choices of n and p1 the proposed SAEWMA-Sign chart performs more efficiently relative to the EWMA-Sign chart. These results show that the proposed SAEWMA-Sign chart is far better than EWMA-Sign chart in terms of detecting all levels of shifts.

Tab. 4. ARL values of the proposed and existing control charts when λ = 0.05 for different levels of n.
<i>ARL</i> values of the proposed and existing control charts when λ = 0.05 for different levels of <i>n</i>.

3.1.2. Proposed Vs AEWMA-Sign

The ARL values of the AEWMA-Sign chart and proposed chart are compared in Table 4 at various kinds of shifts. Based on Table 4, we observed that the proposed SAEWMA-Sign chart has significantly better performance as compared to the AEWMA-Sign chart, (for example, with n = 15, p1 = 0.51,0.53,0.55 and 0.7 the ARL of proposed SAEWMA-Sign chart are ARL1 = 188,63,31,6 against ARL1 = 255,81,38,6 for the AEWMA-Sign chart). From these results, we noticed a significantly better performance of the SAEWMA-sign chart compared to AEWMA-sign chart.

3.1.3. Proposed Vs CUSUM-Sign

The ARL values of the CUSUM-Sign chart are reported in Table 4. From Table 4, it is revealed that the ARL1 of the proposed SAEWMA-Sign chart is lower than CUSUM-Sign, under all shifts in the process location (for example, with n = 15, p1 = 0.51,0.53,0.55 and 0.7, of the ARLs of the proposed SAEWMA-Sign chart are ARL1 = 188,63,31,6 against ARL values of CUSUM-Sign chart are, which are ARL1 = 303,117,49,6). The above mentioned results clearly indicates that the superiority of the proposed SAEWMA-Sign chart against the CUSUM-Sign chart for all levels of shifts.

3.2. A comparative analysis among single, double, repetitive and sequential sampling based charting schemes

In this section, we present a comparison of various charting schemes based on single, double, repetitive and sequential sampling mechanisms. We have evaluated the performance of all of these schemes in term of ARL, for varying shifts in location, by considering different widths of indecisive zones for some useful combinations of φ and p1 (cf. Table 5). In order to strengthen the findings of our comparative analysis, we have also computed the results of the average number of samples used (for single, double, repetitive and sequential schemes) for in-control and out-of-control processes. These results are reported in Table 6 for the same combinations of φ and p1, as used for Table 5.

Tab. 5. ARL values of single, DS, RS and SS schemes when λ = 0.05 and n = 10.
<i>ARL</i> values of single, DS, RS and SS schemes when <i>λ</i> = 0.05 and <i>n</i> = 10.
Tab. 6. Average number of samples in the indecisive region for DS, RS and SS at λ = 0.05 and n = 10.
Average number of samples in the indecisive region for DS, RS and SS at <i>λ</i> = 0.05 and <i>n</i> = 10.

The comparative analysis reveals the following:

  • The SS scheme detects the shifts more efficiently as compared to the single, DS and RS schemes. For instance, at p1 = 0.51 and φ = 0.1 the ARL1 values are 289, 221, 298 and 214 for single, DS, RS and SS schemes, respectively, as may be seen in Table 5.

  • The average sample size for DS, RS and SS schemes (cf. Table 6) reveals that the SS scheme gains an edge over other scheme (for almost all shifts levels) with a marginal increase in the average number of samples used (cf. Table 5). For instance, if p1 = 0.52 and φ = 0.1, the average number of samples used are 10.822, 11.167 and 10.875 for DS, RS and SS schemes respectively (cf. Table 6).

  • The performance of the DS and SS schemes are in close competition, especially when p1>0.54 (cf. Table 5). The performance of the SS scheme is relatively better than the single, DS and RS schemes when 0.51≤p1≤0.54 (cf. Table 5).

  • With an increase in the width of indecisive zone (i.e. φ), the SS scheme gets an advantage over others, followed by the superiority of DS. It is to be noted that RS scheme behaves in a reverse manner, the reason being ignoring the sample falling in indecisive zone. In real applications, having a wider indecisive zone may not be very practical, and hence we have chosen the indecisive regions of practical worth.

Therefore, we can say that the proposed chart based on SS scheme offers an efficient charting structure that is relatively better in detecting all levels of shifts, as compared to the existing control charts, considered in this study.

4. A real-life application on smartphone accelerometer data

In this section, we provide a real-life application of an accelerometer data-set for the proposed and the other schemes, considered in this study. An accelerometer is a device which has extensive variety of applications in various fields, such as to measure vibration on machines, cars, air blast pressure, earthquake and aftershocks etc. In this study, we have selected the smartphone accelerometer data-set for the monitoring purpose. This application presents the enactment of control charts for accelerometer data monitoring. We have selected total 50 subgroups of size 10 for this study (cf. Riaz et al. [29]). For the construction of the proposed and the AEWMA-Sign schemes, we used the following parameters, λ = 0.25, L1 = 3.492, L2 = 3.026, P = 0.06, L = 3.291 and ARL0≅370.

The monitoring statistics given in (2) and (6) of the proposed SAEWMA-sign and the AEWMA-sign charts are thus constructed using the control limits given in (3) and (6), respectively. By observing the charts in Fig 4, following observations can be made for the smartphone accelerometer data-set:

  • The AEWMA-Sign scheme proposed by Yang et al. [24] shows an out-of-control signal at sample # 30 (cf. Fig 4).

  • The proposed SAEWMA chart based on the SS scheme offers three out-of- control signals at sample points 29, 30 and 31 (cf. Fig 4), which indicates the quick and better shift detection ability of the proposed scheme as compared to the AEWMA-Sign scheme.

A real-life application using data-set of smartphone accelerometer.
Fig. 4. A real-life application using data-set of smartphone accelerometer.

We may conclude that the proposed scheme outshines the AEWMA-Sign scheme for detecting shifts in process location of the smartphone accelerometer data. The real life application also supported the finding in Section 3.

5. Summary, conclusions and recommendations

An efficient sampling strategy can be very effective in reducing the amount of waste produced by a process. Sequential sampling is one such mechanism. In this study, we have introduced a nonparametric arcsine EWMA sign chart, namely the SAEWMA-sign chart, based on the sequential sampling, in order to increase the detection ability of the arcsine EWMA sign chart. This performance analysis revealed that the proposed chart is an efficient chart that offers higher sensitivity to different types of changes in process parameters. It is also revealed that the proposed chart has quicker shift detection ability under all the design parameters as compared to the competing charts including EWMA-Sign, the AEWMA-Sign and the CUSUM-Sign charts. A real-life data set based on smartphone accelerometer is presented for the implementation of the proposed chart. The said application favors the new chart as a more beneficial statistical tool to detect abnormalities in process location.

The scope of this study may be extended to various other directions for future research such as memory charts for attributes and variables, single and multivariate quality characteristics of the process, under sequential sampling mechanism. Moreover, the proposed chart can be further investigated for parent skewed process distributions.

Supporting information

S1 Dataset [docx]


Zdroje

1. Montgomery DC. Introduction to Statistical Quality Control. 6th Edition, Wiley, New York; 2009.

2. Shewhart WA. Economic Control of Quality Manufactured Product. Van Nostrand, New York, 1931. (reprinted by the American Society for Quality Control in 1980, Milwauker, WI).

3. Page ES. Continuous inspection schemes. Biometrika. 1931; 41: 100–115.

4. Roberts SW. Control chart tests based on geometric moving averages. Technometrics. 1959; 3: 239–250.

5. Chakraborti S, Van der Lann, Bakir ST. Nonparametric control charts: An overview and some results. Journal of Quality Technology. 2001; 33: 304–315.

6. Hoboken NJ, Coehlo MLI, Graham MA, Chakraborti S. Nonparametric signed-rank control charts with variable sampling intervals. Quality and Reliability Engineering International. 2017; 33: 2181–2192.

7. Mukherjee A. Sen R. Optimal design of Shewhart-Lepage type schemes and its application in monitoring service quality. European Journal of Operational Research. 2018; 266: 147–167.

8. Triantafyllou IS. Nonparametric control charts based on order statistics: some advances. Communication in Statistics: Simulation and Computation. 2018; 47: 2684–2702.

9. Qiu P. Some perspectives on nonparametric statistical process control. Journal of Quality Technology. 2018; 50: 49–65.

10. Koutras MV, Triantafyllou IS. A general class of nonparametric control charts, Quality and Reliability Engineering International. 2018; 34: 427–435.

11. Abid M, Nazir HZ, Tahir M, Riaz M. On designing a new cumulative sum Wilcoxon signed for monitoring process location. PLOS ONE. 2018; 13: e0195762. doi: 10.1371/journal.pone.0195762 29664919

12. Li C, Mukherjee A. Su Q. A distribution-free Phase I monitoring scheme for subgroup location and scale based on the multi-sample Lepage statistic. Computers and Industrial Engineering. 2019; 129: 259–273.

13. Triantafyllou IS. A new distribution-free control scheme based on order statistics. Journal of Nonparametric Statistics. 2019 31: 1–30.

14. Chakraborti S, Graham MA. Nonparametric Statistical Process Control. John Wiley and Sons, 2019.

15. Croasdale R. Control charts for a double-sampling scheme based on average production run lengths. International Journal of Production Research. 1974; 12: 585–592.

16. Al-Omari AI, Bouza CN. Review of ranked set sampling: modifications and applications. Revista Investigación Operacional. 2014; 3: 215–240.

17. Haq A.; Brown J.; Moltchanova E. New synthetic EWMA and synthetic CUSUM control charts for monitoring the process mean. Quality and Reliability Engineering International. 2016; 32: 269–290.

18. Aslam M, Azam M, Jun C-H. A mixed repetitive sampling plan based on process capability index. Applied Mathematical Modelling. 2013; 37: 10027–10035.

19. Aslam M, Azam M, Jun C-H. A new exponentially weighted moving average sign chart using repetitive sampling. Journal of Process Control. 2014; 24: 1149–1153.

20. Lee LY, Khoo MBC, Teh SY, Lee MH. A variable sampling interval synthetic Xbar chart for the process mean. PLOS ONE. 2015; 10: e0126331. doi: 10.1371/journal.pone.0126331 25951141

21. Yue J, Liu L. Multivariate nonparametric control chart with variable sampling interval. Applied Mathematical Modelling. 2017; 52: 603–612.

22. Balamurali S, Jun C-H. Repetitive group sampling procedure for variables inspection. Journal of Applied Statistics. 2006; 33: 327–338.

23. Wald A. Sequential Analysis of Statistical Data: Theory. Statistical Research Group, Columbia University. 1943.

24. Yang SF, Lin JS, Cheng SW. A new non-parametric EWMA sign control chart. Expert Systems with Applications. 2011; 38: 6239–6243.

25. Yang SF, Cheng SW. A new non-parametric CUSUM mean chart. Quality and Reliability Engineering International. 2010; 27: 867–875.

26. Koti KM, Babu GJ. Sign test for ranked-set sampling. Communication in Statistics Theory and Methods. 1996; 25: 1617–1630.

27. Abbasi SA. A new nonparametric EWMA sign control chart. Expert Systems with Applications. 2012; 39: 8503.

28. Dyer JN. Monte Carlo simulation design for evaluating normal-based control chart properties. Journal of Modern Applied Statistical Methods. 2016; 15: 580–626.

29. Riaz M, Khaliq Q-U-A, Gul S. Mixed Tukey EWMA-CUSUM control chart and its applications. Quality Technology and Quantitative Management. 2017; 14: 378–411.


Článek vyšel v časopise

PLOS One


2019 Číslo 11
Nejčtenější tento týden
Nejčtenější v tomto čísle
Kurzy

Zvyšte si kvalifikaci online z pohodlí domova

Svět praktické medicíny 1/2024 (znalostní test z časopisu)
nový kurz

Koncepce osteologické péče pro gynekology a praktické lékaře
Autoři: MUDr. František Šenk

Sekvenční léčba schizofrenie
Autoři: MUDr. Jana Hořínková

Hypertenze a hypercholesterolémie – synergický efekt léčby
Autoři: prof. MUDr. Hana Rosolová, DrSc.

Význam metforminu pro „udržitelnou“ terapii diabetu
Autoři: prof. MUDr. Milan Kvapil, CSc., MBA

Všechny kurzy
Kurzy Podcasty Doporučená témata Časopisy
Přihlášení
Zapomenuté heslo

Zadejte e-mailovou adresu, se kterou jste vytvářel(a) účet, budou Vám na ni zaslány informace k nastavení nového hesla.

Přihlášení

Nemáte účet?  Registrujte se

#ADS_BOTTOM_SCRIPTS#