-
Články
Top novinky
Reklama- Vzdělávání
- Časopisy
Top články
Nové číslo
- Témata
Top novinky
Reklama- Kongresy
- Videa
- Podcasty
Nové podcasty
Reklama- Kariéra
Doporučené pozice
Reklama- Praxe
Top novinky
ReklamaA-06 COMPARISON OF ERYTHROCYTE, LEUKOCYTE AND PROGENITOR CELLS COUNT IN LIPOASPIRATE COLLECTED USING VARIOUS LIPOSUCTION TECHNIQUES
Authors: I. Justan 1; E. Trupar 2; J. Skopalík 3
Authors place of work: Surgal Clinic, Department of Plastic and Aesthetic Surgery, Brno, Czech Republic 1; Burn Unit, University Hospital Brno, Brno, Czech Republic 2; Center of Biomedical Engineering - International Clinical Research Center, St. Anne University Hospital Brno, Czech Republic 3
Published in the journal: ACTA CHIRURGIAE PLASTICAE, 57, 3-4, 2015, pp. 54-55
Category: Selected abstracts from the 36th national congress of the czech society plastic surgery with international participation
Introduction
Lipografting has recently become a relatively common technique. Our team has performed a pilot project in the year 2012 with aesthetic augmentation of the breasts, during which was administered fat enriched with autologous cells with stromal vascular fraction (SVF). Cells in SVF are usually obtained for aesthetic procedures by filtration of a part of collected lipoaspirate and then they are used to enrich the lipoaspirate intended for autologous application. Isolated concentrated cell mixture of SVF consists of pre-adipocytes, fibroblasts, endothelial cells, pericytes and precursors of mesenchymal stromal cells (MSC). According to various studies, these precursors of MSC cells play an important role in long term take of fatty tissue and its subsequent growth. Their number and viability in collected lipoaspirate and in isolated SVF is therefore one of the important parameters. The study analyzes the yield and vitality of SVF (or MSC cells) and also the yield and vitality of adipocytes in lipoaspirates harvested with various manual and machine harvesting methods.
Methods
Lipoaspirate was harvested in totally 8 volunteers. There were the following techniques used for harvesting of lipoaspirate: 1) manual technique according to Coleman using 10 ml syringes, 2) suction using piston suction device Medela Dominant 50® with high vacuum -90kPa (i.e. -675 mmHg), with moderate vacuum around -60 kPa (i.e. -450 mmHg) and with low vacuum -30 kPa (i.e. -225 mmHg), 3) Microair PAL 650 System Liposculptor® – vibration liposuction device with vibration mode 4000/minute and with reduced vibration mode 2800/minute, 4) rotation oscillation liposuction of the Swiss company Bien-Air® with frequency of oscillation 2000/minute and 5) Body-jet® device, the harvesting cannula of which features a water microjet. Cannulas used for harvesting had a diameter of 3 mm and 4 mm and they were part of the equipment of the individual manufacturer’s device. Manual suctioning was performed using the cannula from the company Microair after switching off vibration. Harvested samples of lipoaspirate (harvested in the same area in one patient using different methods) were compared from the point of cell yield, viability of adipocytes, yield of SVF, admixture of red cells and long term viability of MSC cells. For the isolation of SVF from lipoaspirate was used the method of enzymatic tissue release. After 24 and 7 days was microscopically quantified the number of adherent MSCs.
Results
The diameter of the cannula, vacuum level and intensity of vibration mode have an effect on the content of viable SVF cells and amount of harvested MSCs. The number of SVF cells for each method was within a wide range of 11 to 22 x 106 (isolation from 5 ml of lipoaspirate). The greatest yield of SVF from the aforementioned methods 1) to 4) was achieved with the use of 3 mm cannula with adjusted maximal vacuum and reduced vibration (22 ± 3 x 10 3 from 5 ml of lipoaspirate). The yield of viable MSC cells was however higher for 4 mm cannula during reduced intensity of vibrations and vacuum (79 ± 18 from 5 ml of lipoaspirate after 24 hour adherence). High vacuum level increases admixture of erythrocytes during isolation of SVF fraction (up to 900 x 103erythrocytes during isolation from 5 ml of lipoaspirate), which is probably related with the damage of capillaries. High vacuum pressure also reduces the number of intact and viable adipocytes. The technique v) was compared with other harvesting techniques on a special group of samples, and showed higher yield of SVF and viable MSCs (650 ± 90 adherent cells in 5 ml of fat), but not intact adipocytes.
Conclusion
The result of our study shows that it is not simple to find a single method for harvesting good quality lipoaspirate, which would also contain a maximal amount of intact viable adipocytes and viable MSCs. It seems that more gentle harvesting methods with low vacuum are ideal for harvesting the best quality adipocyte fraction in lipoaspirate. Cannulas with greater diameter, using vibrations and high vacuum showed increased amount of erythrocyte admixture. The harvesting technique using water jet shows low damage of microvessels, which is especially suitable for effective isolation of SVF.
Štítky
Chirurgie plastická Ortopedie Popáleninová medicína Traumatologie
Článek vyšel v časopiseActa chirurgiae plasticae
Nejčtenější tento týden
2015 Číslo 3-4- Metamizol jako analgetikum první volby: kdy, pro koho, jak a proč?
- S MUDr. Kamilou Kotíkovou o novém pilíři včasné diagnostiky osteoporózy − denzitometrii v gynekologické praxi
- Příčiny a možnosti ovlivnění bolesti předního kolene po implantaci totální endoprotézy
- Osteoporóza v praxi: Kdy léčit v primární péči a kdy referovat do osteocentra?
-
Všechny články tohoto čísla
- Editorial
- 36th NATIONAL CONGRESS OF THE CZECH SOCIETY OF PLASTIC SURGERY WITH INTERNATIONAL PARTICIPATION
- A-01 RECONSTRUCTION OF DEFECTS WITH FOREHEAD FLAP
- A-02 SUBMENTAL AND SUPRACLAVICULAR FLAP
- A-03 “Facial Makeover” – new usage of orthognatHic surgery to improve aesthetics of the face
- A-04 Use of 3D planning in primary microsurgical reconstruction of a facial defect
- A-05 LID IMPLANTS IN THE THERAPY OF LAGOPHTHALMUS
- A-06 COMPARISON OF ERYTHROCYTE, LEUKOCYTE AND PROGENITOR CELLS COUNT IN LIPOASPIRATE COLLECTED USING VARIOUS LIPOSUCTION TECHNIQUES
- A-07 Allogenous acellular dermal matrix in breast reconstruction – our experiences
- A-08 Use of NPWT during reconstructive procedures in plastic surgery
- A-09 Plasmatherapy in chronic skin defects – results of a prospective study
- A-10 Reconstruction of traumatic defects of distal third of the calf with a fasciocutaneous sural flap – our experience
- A-11 Anesthesia and recurrence of malignant melanoma
- A-12 Low osteoplastic amputation of the calf using vascularized bone graf
- A-13 BARRIER EFFICIENCY OF POLYURETHANE FOIL IN PREVENTION OF POSTOPERATIVE INFECTION IN FREE MUSCLE FLAPS
- A-14 SSM WITH IMPLANT RECONSTRUCTION
- A-15 PATIENT SATISFACTION AFTER TWO STAGE IMMEDIATE BREAST RECONSTRUCTION – RETROSPECTIVE STUDY
- A-16 COMPLICATION OF IMMEDIATE TWO STAGE BREAST RECONSTRUCTION AFTER MASTECTOMY
- A-17 Primary breast reconstruction with an implant
- A-18 Two methods to improve vascular supply of a DIEP flap
- Dorzoradiální lalok z předloktí v kombinaci se silikonovým spacerem při rekonstrukci kombinovaného devastačního poranění palce – kazuistika
-
ZORA JANŽEKOVIČ
(September 30, 1918 – March 17, 2015) - Rejstříky
- Acta chirurgiae plasticae
- Archiv čísel
- Aktuální číslo
- Informace o časopisu
Nejčtenější v tomto čísle- 36th NATIONAL CONGRESS OF THE CZECH SOCIETY OF PLASTIC SURGERY WITH INTERNATIONAL PARTICIPATION
-
ZORA JANŽEKOVIČ
(September 30, 1918 – March 17, 2015) - Dorzoradiální lalok z předloktí v kombinaci se silikonovým spacerem při rekonstrukci kombinovaného devastačního poranění palce – kazuistika
- Editorial
Kurzy
Zvyšte si kvalifikaci online z pohodlí domova
Autoři: prof. MUDr. Vladimír Palička, CSc., Dr.h.c., doc. MUDr. Václav Vyskočil, Ph.D., MUDr. Petr Kasalický, CSc., MUDr. Jan Rosa, Ing. Pavel Havlík, Ing. Jan Adam, Hana Hejnová, DiS., Jana Křenková
Autoři: MUDr. Irena Krčmová, CSc.
Autoři: MDDr. Eleonóra Ivančová, PhD., MHA
Autoři: prof. MUDr. Eva Kubala Havrdová, DrSc.
Všechny kurzyPřihlášení#ADS_BOTTOM_SCRIPTS#Zapomenuté hesloZadejte e-mailovou adresu, se kterou jste vytvářel(a) účet, budou Vám na ni zaslány informace k nastavení nového hesla.
- Vzdělávání