#PAGE_PARAMS# #ADS_HEAD_SCRIPTS# #MICRODATA#

Metric Causes of Refractive Errors of the Eye


Metric Causes of Refractive Errors of the Eye

Aims: To confirm current knowledge about the causes of refractive errors in adults. To evaluate the influence of systemic, i.e., primary curvature and, on the other hand, axial causes of refractive errors of the eye, in comparison with the Gullstrand model of the eye expressed by axial length and corneal curvature ratio.

Material and Methods: The basic sample included 60 eyes of 30 subjects with an average age of 22.3 ±1.1 years. There were 3 men and 27 women in the group. They were young, generally healthy individuals, without serious eye pathologies. The basic sample was divided into research (n = 36) and control group (n = 24). We measured the axial length of the eye using the IOL MASTER 500 optical biometer (Carl Zeiss Meditec, Jena, Germany). We measured the topographic and keratometric values ​​of the cornea using the Pentacam HR device (Oculus GmbH, Wetzlar, Germany). We obtained the objective refraction values ​​by measuring them on a standard instrument automatic refractometer TRK-1P (Topcon Corp., Tokyo, Japan). We determined the axial length of the eye (AXD), the average value of keratometry (KRT) and the spherical equivalent of the refractive error (SE) as significant variables. The evaluation of variables was carried out by comparison with the Gullstrand model of the eye.

Results: We calculated the ratios of the median axial length of the eye and the median keratometry in the research group with myopia (AXD/KRTM = 3.18 with IQR 0.1) and the control group (AXD/KRTK = 2.93 with IQR 0.1). The difference between the two groups was statistically significant (p < 0.001). The percentage expression of axial and curvature causes of ametropia was 72/28% in the myopic group and 83/17% in the control group.

Conclusion: Our study confirmed that the AXD/KRT parameter is a significant indicator of the cause of the refractive state of the eye, with the important influence of axial length on this parameter.

Keywords:

Pentacam – keratometry – axial length – optical biometer – refractometry


Autoři: Petr Veselý 1,2;  Pavel Beneš 1,2;  Jana Šidlová Sokolová 2;  Petra Záděrová 2;  Hana Došková 1,2
Působiště autorů: Department of Ophthalmology and Optometry, St. Anna University Hospital, Brno, Czech Republic 1;  Department of Optometry and Orthoptics, Faculty of Medicine, Masaryk University, Brno, Czech Republic 2
Vyšlo v časopise: Čes. a slov. Oftal., 81, 2025, No. Ahead of Print, p. 1-4
Kategorie: Původní práce
doi: https://doi.org/10.31348/2025/40

Souhrn

Aims: To confirm current knowledge about the causes of refractive errors in adults. To evaluate the influence of systemic, i.e., primary curvature and, on the other hand, axial causes of refractive errors of the eye, in comparison with the Gullstrand model of the eye expressed by axial length and corneal curvature ratio.

Material and Methods: The basic sample included 60 eyes of 30 subjects with an average age of 22.3 ±1.1 years. There were 3 men and 27 women in the group. They were young, generally healthy individuals, without serious eye pathologies. The basic sample was divided into research (n = 36) and control group (n = 24). We measured the axial length of the eye using the IOL MASTER 500 optical biometer (Carl Zeiss Meditec, Jena, Germany). We measured the topographic and keratometric values ​​of the cornea using the Pentacam HR device (Oculus GmbH, Wetzlar, Germany). We obtained the objective refraction values ​​by measuring them on a standard instrument automatic refractometer TRK-1P (Topcon Corp., Tokyo, Japan). We determined the axial length of the eye (AXD), the average value of keratometry (KRT) and the spherical equivalent of the refractive error (SE) as significant variables. The evaluation of variables was carried out by comparison with the Gullstrand model of the eye.

Results: We calculated the ratios of the median axial length of the eye and the median keratometry in the research group with myopia (AXD/KRTM = 3.18 with IQR 0.1) and the control group (AXD/KRTK = 2.93 with IQR 0.1). The difference between the two groups was statistically significant (p < 0.001). The percentage expression of axial and curvature causes of ametropia was 72/28% in the myopic group and 83/17% in the control group.

Conclusion: Our study confirmed that the AXD/KRT parameter is a significant indicator of the cause of the refractive state of the eye, with the important influence of axial length on this parameter.

Stránka

Štítky
Oftalmologie

Článek vyšel v časopise

Česká a slovenská oftalmologie

Číslo Ahead of Print

2025 Číslo Ahead of Print
Nejčtenější tento týden
Nejčtenější v tomto čísle
Kurzy

Zvyšte si kvalifikaci online z pohodlí domova

Svět praktické medicíny 4/2025 (znalostní test z časopisu)
nový kurz

Denzitometrie v praxi: od kvalitního snímku po správnou interpretaci
Autoři: prof. MUDr. Vladimír Palička, CSc., Dr.h.c., doc. MUDr. Václav Vyskočil, Ph.D., MUDr. Petr Kasalický, CSc., MUDr. Jan Rosa, Ing. Pavel Havlík, Ing. Jan Adam, Hana Hejnová, DiS., Jana Křenková

Eozinofilie – multioborová otázka?
Autoři: MUDr. Irena Krčmová, CSc.

Čelistně-ortodontické kazuistiky od A do Z
Autoři: MDDr. Eleonóra Ivančová, PhD., MHA

Cesta od prvních příznaků RS k optimální léčbě
Autoři: prof. MUDr. Eva Kubala Havrdová, DrSc.

Všechny kurzy
Kurzy Podcasty Doporučená témata Časopisy
Přihlášení
Zapomenuté heslo

Zadejte e-mailovou adresu, se kterou jste vytvářel(a) účet, budou Vám na ni zaslány informace k nastavení nového hesla.

Přihlášení

Nemáte účet?  Registrujte se

#ADS_BOTTOM_SCRIPTS#