#PAGE_PARAMS# #ADS_HEAD_SCRIPTS# #MICRODATA#

Use of instrument technology in rehabilitation – practical experience


Authors: Ragulová M. 1;  Pavlů D. 1;  Dvořák T. 2
Authors‘ workplace: Katedra fyzioterapie, Fakulta tělesné výchovy a sportu, Univerzita Karlova, Praha 1;  MONADA, spol. s. r. o. – Klinika komplexní rehabilitace 2
Published in: Rehabil. fyz. Lék., 29, 2022, No. 3, pp. 151-157.
Category:
doi: https://doi.org/10.48095/ccrhfl2022151

Overview

The authors point out the possibilities of using two devices – a 3D scanner and ultrasound examination in the practice of a physiotherapist. They present a case study of a patient after knee joint distortion with limited extension of the knee joint persisting after repeated arthroscopic operations and ongoing rehabilitation although the time of treatment should normally be sufficient for resolving the problem, and demonstrate the simplicity and benefits of these new methods, which seem to be a suitable complement to assessment procedures used in rehabilitation.

Keywords:

3D scanner – Physiotherapy – rehabilitation – ultrasonography – knee – new methods


Sources

1. Đonlić M, Petković T, Peharec S et al. On the segmentation of scanned 3D human body models. 8th Intern Sci Conf Kinesiol 2017, Opatija, Croatia. [online]. Available from: file:///C:/Users/Uzivatel/Downloads/875035.On_the_Segmentation_of_Scanned_3D_Human_Body_Models.pdf.

2. Daanen H, Har F. 3D whole body scanners revisited. Displays 2013; 34(4): 270–275. doi: 10.1016/j.displa.2013.08.011.

3. Skenování ve 3D. Využití 3D skenování v lékařství. [online]. Dostupné z: https://www.skenovanive3d.cz/skenovani/kde-skener-vyuzit/lekarstvi/.

4. Gelb HJ, Glasgow SG, Sapega AA et al. Magnetic resonance imaging of knee disorders: clin­ical value and cost-effectiveness in a sports med­icine practice. Am J Sports Med 1996; 24(1): ­99–103. doi: 10.1177/036354659602400118.

5. Kälebo P, Swärd L., Karlsson J et al. Ultrasonography in the detection of partial patellar ligament ruptures (jumper’s knee). Skeletal Radiol 1991; 20(4): 285–289. doi: 10.1007/BF02341668.

6. Kelsch G, Ulrich C, Bickelhaupt A. Ultrasound imaging of the anterior cruciate ligament. Pos­sibilities and limits. Unfallchirurg 1996; 99(2): 119–123.

7. Kremkau FW. Diagnostic Ultrasound. Principles and Instruments. Philadelphia: WB Saunders 1998.

8. Laine HR, Harjula A, Peltokallio P. Ultrasound in the evaluation of the knee and patellar regions. J Ultrasound Med 1987; 6(1): 33–36 doi: 10.7863/jum.1987.6.1.33.

9. Mezian K, Steyerová P, Vacek J et al. Úvod do neuromuskulární ultrasonografie. Česk Slov Neurol N 2016; 79/112(6): 656–661. doi: 10.14735/amcsnn2016656.

10. Roberts CS, Beck DJ Jr, Heinsen J et al. Review article: diagnostic ultrasonography: applications in orthopaedic surgery. Clin Orthop Relat Res 2002; 401: 248–264. doi: 10.1097/00003086-200208000-00028.

11.Van Holsbeec MT et al. Physical principles of ultrasound imaging. In: Bralow L (ed). Musculo­skeletal Ultrasound 2001; 2: 1–7.

12. Paczesny Ł, Kruczyński J. Ultrasound of the knee. Semin Ultrasound CT MR 2011; 32(2): ­114–124. doi: 10.1053/j.sult.2010.11.002.

13. Yao AWL. Applications of 3D scanning and reverse engineering techniques for quality control of quick response products. Int J Adv Manuf Technol 2005; 26(11): 1284–1288. doi: 10.1007/s00170-004-2116-5.

14. Ortotika. Kraniosynostóza. [online]. Dostupné z: https://www.ortotika.cz/kranialni-ortezy.

15. Chahaki E, Javanshir M, Saeeidi H et al. Investigating the prevalence of positional plagiocephaly with 3D scan in children under one year of age in Mofid hospital. Func Disabil J 2021; 4(1): 33–33.

16. Geoffroy M, Gardar J, Goodnough J et al. Cranial remodeling orthosis for infantile plagio­cephaly created through a 3D scan, topological optimization, and 3D printing process. J Pros­thet Orthot 2018; 30(4): 247–258. doi: 10.1097/JPO.0000000000000190.

17. Kim T, Cho Y, Chang M et al. Tooth segmentation of 3D scan data using generative adversarial networks. Applied Sciences 2020; 10(2): 490. doi: 10.3390/app10020490.

18. Barreto MS, Faber J, Vogel CJ et al. Reliabil­ity of digital orthodontic setups. Angle Orthod 2016; 86(2): 255–259. doi: 10.2319/120914-890.1.

19. Telfer S, Yi JS, Kweon CY et al. Monitoring changes in knee surface morphology after anterior cruciate ligament reconstruction surgery using 3D surface scanning. Knee 2020; 27(1): 207–213. doi: 10.1016/j.knee.2019.10.004.

20. Dessery Y, Pallari J. Correction: Measurements agreement between low-cost and high-level handheld 3D scanners to scan the knee for designing a 3D printed knee brace. PLoS One 2018; 13(4): e0196183. doi: 10.1371/journal.pone.0196183.

21. Richter J, Dàvid A, Pape HG et al. Diagnosis of acute rupture of the anterior cruciate ligament. Value of ultrasonic in addition to clinical examination. Unfallchirurg 1996; 99(2): 124–129.

22. Zeng H, Kang B, Liu G et al. Ultrasonographic diagnosis of bone tumor of the knee and its clin­ical implication. J Tongji Med Univ 2001; 21(3): 236–237, 245. doi: 10.1007/BF02886440.

23. Wada A, Fujii T, Takamura K et al. Congenital dislocation of the patella. J Child Orthop 2008; 2(2): 119–123. doi: 10.1007%2Fs11832-008-0090-4.

24. Guiral J, Rodrigo A, Tello E. Subcutaneous echinococcosis of the knee. Lancet 2004; 363(9402): 38. doi: 10.1016/S0140-6736(03)15168-9.

25. Eşen S, Akarırmak U, Aydın FY et al. Clinical evaluation during the acute exacerbation of knee osteoarthritis: the impact of diagnostic ultrasonography. Rheumatol Int 2013; 33(3): ­711–717. doi: 10.1007/s00296-012-2441-1.

26. Terslev L, Qvistgaard E, Torp-Pedersen S et al. Ultrasound and Power Doppler findings in jumpers knee – preliminary observations. Eur J Ultrasound 2001; 13(3): 183–189. doi: 10.1016/S0929-8266(01)00130-6.

27. Mandl P, Brossard M, Aegerter P et al. Ultrasound evaluation of fluid in knee recesses at varying degrees of flexion. Arthritis Care Res 2012; 64(5): 773–779. doi: 10.1002/acr.21598.

28. Basha MAA, Eldib DB, Aly SA et al. Diagnostic accuracy of ultrasonography in the assessment of anterior knee pain. Insights Imaging 2020; 11(1): 107. doi: 10.1186/s13244-020-00914-2.

29. Hrazdira L (ed). Praktická muskuloskeletální ultrasonografie pro lékaře a fyzioterapeuty. Paido 2020. ISBN 978-80-7315-270-3.

30. Thomas AC, Wojtys EM, Brandon C et al. Muscle atrophy contributes to quadriceps weakness after anterior cruciate ligament reconstruction. J Sci Med Sport 2016; 19(1): 7–11. doi: 10.1016/j.jsams.2014.12.009.

31. Palmieri-Smith RM, Kreinbrink J, Ashton-Mil­ler JA et al. Quadriceps inhibition induced by an experimental knee joint effusion affects knee joint mechanics during a single-legged drop landing. Am J Sports Med; 35(8): 1269–1275. doi: 10.1177/0363546506296417.

Labels
Physiotherapist, university degree Rehabilitation Sports medicine
Login
Forgotten password

Enter the email address that you registered with. We will send you instructions on how to set a new password.

Login

Don‘t have an account?  Create new account

#ADS_BOTTOM_SCRIPTS#