Treatment of post-traumatic tibial defect by callus distraction using a magnetic intramedullary nail – first experiences
Authors:
R. Veselý 1; R. Zukal 1; J. Kacián 2
Authors‘ workplace:
Klinika traumatologie LF MU a Úrazová nemocnice v Brně
1; Oddelenie úrazovej chirurgie, FNsP Žilina
2
Published in:
Rozhl. Chir., 2026, roč. 105, č. 10, s. 463-469.
Category:
Case Report
doi:
https://doi.org/10.48095/ccrvch2026463
Overview
In a case report of soft tissue and skeletal loss involving the tibial diaphysis in a patient following a motorcycle accident, the authors present the first use of a magnetic intramedullary lengthening nail. The nail was applied after primary treatment of the complex lower leg injury using an external fixator, followed by resection and acute tibial shortening over an antibiotic-impregnated nail. The defect resulting from the acute abbreviation was managed via callus distraction using the nail, and definitive healing was achieved after restoration of the original length. No complications were recorded during the treatment process.
The method of callus distraction for treating post-traumatic long bone defects using a magnetic intramedullary lengthening nail was used for the first time in the Czech Republic in our patient. Its indisputable advantages include ease of use and patient comfort, as well as excellent control of the distraction process for the trauma surgeon. A further advantage over the widely used method of callus distraction via external fixation is a lower incidence of complications.
Keywords:
callus distraction – magnetic intramedullary nail – post-traumatic defect
Sources
1. Ilizarov GA. The tension-stress effect on the genesis and growth of tissues. Part I. The influence of stability of fixation and soft-tissue preseration. Clin Orthop Relat Res 1989; 238 : 249–281.
2. Veselý R, Procházka V. Kalusdistrakce v léčení poúrazových defektů femuru a tibie. Acta Chir Orthop Traumatol Cech 2016; 83 (6): 388–392.
3. Bost FC, Larsen LJ. Experiences with lengthening of the femur over an intramedullary rod. J Bone Joint Surg Am 1956; 38 (3): 567–584.
4. Baumgart R, Betz A, Schweiberer L. A fully implantable motorized intramedullary nail for limb lengthening and bone transport. Clin Orthop Relat Res 1997; 343 : 135–143.
5. Cole JD, Justin D, Kasparis T et al. The intramedullary skeletal kinetic distractor (ISKD): First clinical results of a new intramedullary nail for lengthening of the femur and tibia. Injury 2001; 32 (Suppl 4): SD129–SD139. doi: 10.1016/s0020-1383 (01) 00116-4.
6. Giuchet JM, Casar RS. Mechanical characterization of a totally intramedullary gradual elongation nail. Clin Orthop Relat Res 1997; 337 : 281–290. doi: 10.1097/00003086-199704000-00032.
7. Rozbruch SR, Birch JG, Dahl MT et al. Motorized intramedullary nail for management of limb-length discrepancy and deformity. J Am Acad Orthop Surg 2014; 22 (7): 403–409. doi: 10.5435/JAAOS-22-07-403.
8. Mazeau P, Assi C, Louahem D et al. Complications of Albizzia femoral lengthening nail: an analysis of 36 cases. J Pediatr Orthop B 2012; 21 (5): 394–399. doi: 10.1097/BPB.0b013e328354b029.
9. Kocaoglu M, Eralp L, Kilcoglu O et al. Complications encountered during lengthening over an intramedullary nail. J Bone Jt Surg Am 2004; 86 (11): 2406–2411. doi: 10.2106/00004623-200411000-00007.
10. Kojimoto H, Yasui N, Goto T et al. Bone lengthening in rabbits by callus distraction. The role of periosteum and endosteum. J Bone Joint Surg Br 1988; 70 (4): 543–549. doi: 10.1302/02301-620X.70B4.3403595.
11. Denckwardt-Lillieström G. Reaming of the medullary cavity and its effect on diaphyseal bone. A fluorochromic, microangiographic and histologic study on the rabbit tibia and dog femur. Acta Orthop Scand Suppl 1969; 128 : 1–153. doi: 10.3109/ort.1969.40.suppl-128.01.
12. Paley D. Precice intramedullary limb lengthening system. Expert Rev Med Devices 2015; 12 (3): 231–249. doi: 10.1586/17434440.2015.1005604.
13. Frost MW, Rahbek O, Traerup J et al. Systemic review of complications with externally controlled motorized intramedullary bone lengthenng nails (FITBONE and PRECICE) in 983 segments. Acta Orthop 2021; 92 (1): 120–127. doi: 10.1080/17453674.2020.1835321.
14. Green SA, Fragomen AT, Herzenberg JEet al. A magnetically controlled lengthening nail: a prospective study of 31 individuals (the PRECICETM intramedullary nail study). J Limb Reconstr 2018; 4 (2): 67–75. doi: 10.4103/jllr.jllr_20_18.
15. Hosny GA. Limb lengthening history, evolution, complications and current concepts. J Orthop Traumatol 2020; 21 (1): 3. doi: 10.1186/s10195-019-0541-3.
Labels
Surgery Orthopaedics Trauma surgeryArticle was published in
Perspectives in Surgery
2026 Issue 10
-
All articles in this issue
- Quo vadis, úrazová chirurgie? O dva roky později
- Sport-related concussion
- Management of an anterior malleolus fracture – a retrospective study
- Treatment outcomes of suprapatellar nailing of distal tibial fractures
- Perioperative management of proximal femur fractures in patients on direct oral anticoagulants
- Fracture related infection after nailing calcaneal fractures using the C-Nail
- Partial rib resection due to risk of injury to the descending thoracic aorta in multiple rib fractures – a case report
- Treatment of post-traumatic tibial defect by callus distraction using a magnetic intramedullary nail – first experiences
- Ještě jednou k centralizaci
- Quo vadis, centralizace? K bezpečnější péči o pacienta
- Světu mír a integrovanou péči, byť by šlo jen o konečník
- Perspectives in Surgery
- Journal archive
- Current issue
- Online only
- About the journal
Most read in this issue
- Sport-related concussion
- Treatment outcomes of suprapatellar nailing of distal tibial fractures
- Fracture related infection after nailing calcaneal fractures using the C-Nail
- Partial rib resection due to risk of injury to the descending thoracic aorta in multiple rib fractures – a case report