#PAGE_PARAMS# #ADS_HEAD_SCRIPTS# #MICRODATA#

Replantation of IMA and Accessory Right RA during Infrarenal AAA Repair and a Current View on Indications for IMA Replanting


Authors: E. Biroš;  R. Staffa;  Z. Kříž
Authors‘ workplace: II. chirurgická klinika LF MU a FN u sv. Anny v Brně, přednosta: prof. MUDr. R. Staffa, Ph. D.
Published in: Rozhl. Chir., 2010, roč. 89, č. 9, s. 551-555.
Category: Monothematic special - Original

Overview

Introduction:
Replanting the inferior mesentery artery during infrarenal aortic aneurysm repair is a measure which might prevent development of colon ischemia under certain circumstances. These circumstances and patients who would benefit from this procedure are not well defined.

Case report:
64-year old man underwent an elective operation on infrarenal AAA at our institution in December 2009. From preoperative CT angiography we knew about the accessory right renal artery branching directly from AAA and bilateral occlusion of hypogastric arteries. We performed open resection of AAA with implantation of a bifurcated graft. Proximal anastomosis was situated below renal arteries, distal anastomoses were bilaterally constructed on external illiac arteries. The accessory right renal artery was anastomosed into the right limb of the graft and IMA was replanted into the body of the graft. Postoperative recovery of the patient was uneventful. His follow-ups 3 and 6 months after the operation have been showing good clinical state of the patient, absence of abdominal complaints and normal levels of urea and creatinine. CT angiography which was performed 3 months after the operation discovered an occlusion of the reimplanted IMA, but patent replanted accessory right renal artery.

Discussion:
Assessment of collateral circulation of large intestine during infrarenal AAA repair is influenced by many preoperative and intraoperative factors. Most surgeons judge the adequacy of the collateral circulation by IMA backbleeding combined with inspection of sigmoid colon after restoring aortic flow. There have been numerous attempts to replace this subjective approach with more objective methods like intraoperative colon mucosal saturation measurement, laser Doppler flowmetry, IMA stump pressures, photophletyzmographic technique. Even though these methods describe conditions when a collateral circulation of rectosigmoid is inadequate after IMA ligature, they are unable to fully eliminate the occurrence of colon ischemia because of its multifactorial nature. Solving the problem of collateral circulation of the large intestine represents only a part of the obstacle presented by colon ischemia after infrarenal AAA repair.

Conclusion:
IMA replantation during infrarenal AAA repair does not fully prevent an occurance of colon ischemia. On the other side, this moneuver does not increase perioperative morbidity, nor prolongs an operation significantly. Our policy is to replant IMA whenever we thing the circulation of large intestine is under threat or in borderline situations.

Key words:
AAA repair – IMA replantation – colon ischemia


Sources

1. Rutherford, R. Vascular Surgery. 6th edition, Saunders, 2005.

2. Kaiser, M. M., Wenk, H., Sassen, R., Müller, G., Bruch, H. P. Ischemic colitis after vascular surgery reconstruction of an abdominal aortic aneurysm. Chirurg, 1996, Apr; 67 (4): 380–386.

3. Cruz, C. P., Drouilhet, J. C., Southern, F. N., Eidt, J. F., Barnes, R. W., Moursi, M. M. Abdominal aortic aneurysm repair. Vasc. Surg., 2001 Sep-Oct; 35(5): 335–344.

4. Champagne, B. J., Darling, R. C. 3rd, Daneshmand, M., Kreienberg, P. B., Lee, E. C., Mehta, M., Roddy, S. P., Chang, B. B., Paty, P. S., Ozsvath, K. J., Shah, D. M. Outcome of aggressive surveillance colonoscopy in ruptured abdominal aortic aneurysm. J. Vasc. Surg., 2004 Apr; 39(4): 792–796.

5. Becquemin, J.-P., Majewski, M., Fermani, N., Marzelle, J. Colon ischemia following abdominal aortic aneurysm repair in the era of endovascular abdominal aortic repair. Journal of Vascular Surgery, 2008 Feb, 47(2): 258–263.

6. Senekowitsch, C., Assadian, A., Assadian, O., Hartleb, H., Ptakovsky, H., Hagmüller, G. W. Replanting the inferior mesentery artery during infrarenal aortic aneurysm repair: influence on postoperative colon ischemia. J. Vasc. Surg., 2006 Apr; 43(4): 689–694.

7. Zelenock, G. B., Strodel, W. E., Knol, J. A., Messina, L. M., Wakefield, T. W., Lindenauer, S. M., Eckhauser, F. E., Greenfield, L. J., Stanley, J. C. A prospective study of clinically and endoscopically documented colonic ischemia in 100 patients undergoing aortic reconstructive surgery with aggressive colonic and direct pelvic revascularization, compared with historic controls. Surgery, 1989 Oct; 106(4): 771–779; discussion 779–780.

8. Björck, M., Berquist, D., Troeng, T. Incidence and clinical presentation of bowel ischemia after aortoiliac surgery – 2930 operations from a population based registry in Sweden. Eur. J. Vasc. Endovasc. Surg., 1996; 12: 139–144.

9. Gourley, E. J., Gering, S. A. The Meandering Mesenteric Artery: A Historic Review and Surgical Implications. Diseases of the Colon & Rectum. New York: May 2005, Vol. 48, Iss. 5; p. 996.

10. Connolly, J. E., Ingegno, M., Wilson, S. E. Preservation of the pelvic circulation during infrarenal aortic surgery. Cardiovasc. Surg., 1996, 4: 65.

11. Dubost, C., Allary, M., Oeconomos, N. Resection of an aneurysm of the abdominal aorta: reestablishment of the continuity by a preserved human arterial graft, with result after five months. Arch. Surg., 1952, 64: 405–408.

12. Mitchell, K. M., Valentine, R. J. Inferior mesenteric artery reimplantation does not guarantee colon viability in aortic surgery. J. Am. Coll. Surg., 2002, 194: 151–155.

13. Israeli, D., Dardik, H., Wolodiger, F., Silvestri, F., Scherl, B., Chessler, R. Pelvic radiation therapy as a risk factor for ischemic colitis complicating abdominal aortic reconstruction. J. Vasc. Surg., 1996 Apr; 23(4): 706–709.

14. Oriel, K., Fjord, W. M., Geary, J. E. Detection of occult colonic ischemia during aortic prodedures: Use of an intraoperative photoplethysmographic technique. J. Vasc. Surg., 1988, 7: 5.

15. Begman, R. Z., Gloviczki, P., Welch, T. J., et al. The role of intravenous fluorescein in the detection of colon ischemia duringn aortic reconstruction. Ann. Vasc. Surg., 1992, 6: 74.

16. Ernst, C. B., Hagihara, P. F., Daugherty, M. E., Griffen, W. O. Inferior mesenteric artery stump pressure: A reliable index for safe IMA ligation during abdominal aortic aneurysmectomy. Ann. Surg., 1978, 187: 641.

17. Abromaitis, D., Antusevas, A. Prevention of intestinal ischemia after abdominal aortic reconstructive surgery. Medicina (Kaunas), 2005; 41(4): 295–304.

18. Lee, E. S., Bass A., Arko, F. R., Heikkinen M. Intraoperative colon mucosal oxygen saturation during aortic surgery. Journal of Surgical Research, 2006, Vol. 136, No 1.: 19–24.

19. Redaelli, C. A., Schilling, M. K., Carrel, T. P. Intraoperative aasessment of intestinal viability by laser Doppler flowmetry for surgery of ruptured abdominal aortic aneurysms. World J. Surg., 1998 Mar, 23 (3): 283–289.

20. Wright, C. B., Hobson, R. W. 2nd Prediction of intestinal viability using Doppler ultrasound technics. Am. J. Surg., 1975, 129: 642–645.

Labels
Surgery Orthopaedics Trauma surgery
Login
Forgotten password

Enter the email address that you registered with. We will send you instructions on how to set a new password.

Login

Don‘t have an account?  Create new account

#ADS_BOTTOM_SCRIPTS#