#PAGE_PARAMS# #ADS_HEAD_SCRIPTS# #MICRODATA#

Evaluation of the Clinical Results of Implantation the Hydrophobic Intraocular Lens CT LUCIA 601P


Authors: A. Stepanov;  N. Jirásková;  P. Rozsíval
Authors‘ workplace: Oční klinika Fakultní nemocnice, Hradec Králové přednosta prof. MUDr. Pavel Rozsíval, CSc., FEBO
Published in: Čes. a slov. Oftal., 71, 2015, No. 4, p. 196-198
Category: Original Article

Práce byla přednesena na sjezdu Futurum Ophthalmologicum, Lázně Bělohrad 16. května 2015.

Overview

Purpose:
To evaluate the properties and clinical outcomes after implantation the new hydrophobic intraocular lens CT LUCIA 601P in patients undergoing routine cataract surgery.

Material and Methods:
The study included 38 patients (43 eyes), mean age 70 ± 8 years (range 56–91 years) with senile cataract. After phacoemulsification intraocular lens CT LUCIA 601P was implanted. Patients were evaluated at 4 months after surgery. We assessed uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), refraction, keratometry and the incidence of posterior capsule opacification (PCO – Posterior capsule opacification).

Results:
Before surgery the mean UCVA was 0.3 ± 0.18 and four months after surgery was 0.7 ± 0.15. The mean BCVA before surgery was 0.58 ± 0.21 and after surgery was 0.94 ± 0.08. PCO value was 0.199 ± 0.05, that means minimal incidence of PCO.

Conclusion:
The new hydrophobic intraocular lens CT LUCIA 601P could be easily implanted and after surgery shows a high degree of biocompatibility in patients undergoing routine cataract surgery.

Key words:
intraocular lens CT LUCIA 601P, posterior capsule opacification, OSCA


Sources

1. Aslam, T., Niall, P., Christopher, R.: OSCA: a comprehensive open-access system of analysis of posterior capsular opacification, BMC Ophthalmology, 2006, 6: 30.

2. Bosc, JM.: Initial impressions and early clinical results of a new single-piece hydrophobic yello acrylic IOL, presented at The ASCRS Symposium on Cataract, IOL, and Refractive Surgery, San Francisco, 2009.

3. Jirásková, N., Rozsíval, P.: Metody hodnocení zkalení zadního pouzdra po operaci katarakty, Čes a Slov Oftal, 2004, 60(2): 155–157.

4. Maedel, S., Hirnschall, N., Chen, YA., Findl, O.: Effect of heparin coating of a foldable intraocular lens on inflammation and capsular bag performance after cataract surgery, J. Cataract Refract Surg, 2013, 39(12): 1810-1817.

5. Pozlerová, J., Nekolová, J., Jirásková, N., et al.: Hodnocení opacit zadního pouzdra u různých typů umělých nitroočních čoček. Čes a Slov Oftal, 2009, 65(1): 12-15.

6. Rosca, G.: High Precision Injection with a New Heparin Coated Hydrophobic One Piece IOL, presented at ASCRS, Chicago, 2012.

7. Stepanov, A., Jirásková, N., Nekolová, J., Lackovič, J., Románek, J., Rozsíval, P.: Evaluation of the clinical results of implantation the hydrophobic-hydrophilic intraocular lens ERIFLEX 877 FAB, Čes a Slov Oftal, 2013, 69(6): 236–238.

8. Žemaitiené, R., Jašinskas, V., Barzdžiukas, V. et al.: Prevention of posterior capsule opacification using different intraocular lenses (result of one-year clinical study), Medicina (Kaunas)., 2004, 40(8): 721–729.