Impact of methodical guidelines of gastric scintigraphy on patients’ radiation exposure


Authors: M. Horváthová;  Z. Bárdyová;  D. Budošová;  R. Husťak
Authors‘ workplace: Gastroenterologická a endoskopická ambulancia, Interná klinika FN Trnava ;  Fakulta zdravotníctva a sociálnej práce TU v Trnave
Published in: Gastroent Hepatol 2021; 75(2): 159-164
Category:
doi: https://doi.org/10.48095/ccgh2020159

Overview

Introduction: Gastric emptying scintigraphy (GES) is a safe, noninvasive method for assessing the ability of the stomach to empty which has been used clinically for many years. It is considered as a “gold standard” to assess gastric emptying of both solids and liquids allowing assessment of early, mid and late emptying, each of which may be altered by pathology. The aim of the study was to analyse standard dia­gnostic approach and evaluate patients` radiation exposure, who underwent GES in Slovakia. Methods: A retrospective cohort study included 55 patients from 2 departments of nuclear medicine (department A, B). Patients’ radiation exposure was determined by dosimetry program IDAC-Dose2.1. The radiopharmaceutical 99mTc-DTPA, always with the same activity, was applied orally to patients at Department B. The applied activity of the radiopharmaceutical at GES was 185 MBq. The radiopharmaceutical 99mTc MAA, with various activity, was applied orally to patients at Department A. Results: According to ICRP60, the effective dose (ED) of every patient undergoing GES was 0.77 mSv and, according to ICRP103, the dose was 0.836 mSv at Department B. Patients at Department A were exposed to ionizing radiation with 5-times lower intensity, compared with patients at Department B. It was caused by radiopharmaceutical activity correction. The ED medians according to ICRP60, and according to ICRP103 were 0.167 mSv (range 0.105–0.208 mSv) and 0.181 mSv (range 0.113–0.226 mSv) at Department A, respectively. Discussion: Adequate correction of applied radiopharmaceutical activity is an essential part of GES guidelines and in accordance with ALARA principles. For the accuracy of GES examination, it is necessary to follow a standard 4-hour protocol and an approach which ensures full-featured utilization of the examination while decreasing patient`s radiation exposure. Conclusion: The results of our study show relatively low ED associated with GES, but also confirm that the GES methodology significantly affects the patient`s radiation exposure.

Conflict of Interest: The authors declare that the article/ manuscript complies with ethical standards, patient anonymity has been respected, and they state that they have no financial, advisory or other commercial interests in relation to the subject matter.

Publication Ethics: This article/ manuscript has not been published or is currently being submitted for another review. The authors agree to publish their name and e-mail in the published article/ manuscript.

Dedication: The article/ manuscript is not supported by a grant nor has it been created with the support of any company.

The Editorial Board declares that the manuscript met the ICMJE “uniform requirements” for bio­medical papers.

Keywords:

effective dose – gastric emptying – nuclear medicine – Radiation exposure – scintigraphy


Sources
  1. Banks KP, Syed K, Parekh M et al. Gastric emptying scan. 2020 [online]. Available from: https:/ / www.ncbi.nlm.nih.gov/ books/ NBK531503/ .
  2. Saadi M, Yu D, Malik Z et al. Pyloric sphincter characteristics using EndoFLIP® in gastroparesis. Rev Gastroenerol Mex 2018; 83(4): 375–384. doi: 10.1016/ j.rgmx.2018.02.013.
  3. Ertay T, Doğan AS, Ulker O et al. 2014. In vitro evaluation of tc-99m radiopharmaceuticals for gastric emptying studies. Mol Imaging Radionucl Ther 2014; 23(1): 21–24. doi: 10.4274/ Mirt.75047.
  4. Shin AS, Camilleri M. Dia­gnostic assessment of diabetic gastroparesis. Diabetes 2013; 62(8): 2667–2673. doi: 10.2337/ db12-1706.
  5. BNMS. Guideline for Gastric Emptying – British Nuclear Medicine Society. 2017 [online]. Available from: https:/ / cdn.ymaws.com/ www.bnms.org.uk/ resource/ resmgr/ guidelines/ gastric_emptying_guidelines_.pdf.
  6. Maurer AH. Gastrointestinal motility, part 1: esophageal transit and gastric emptying. J Nucl Med 2015; 56(8): 1229–1238. doi: 10.2967/ jnumed.112.114314.
  7. Parkman HP. Idiopathic gastroparesis. Gastroenterol Clin North Am 2015; 44(1): 59–68. doi: 10.1016/ j.gtc.2014.11.015.
  8. Seok JW. How to interpret gastric emptying scintigraphy. J Neurogastroenterol Motil 2011;  17(2): 189–191. doi: 10.5056/ jnm.2011.17.2.189.
  9. NCZI SK. Činnosť nukleárnej medicíny, klinickej a radiačnej onkológie v SR. Štatistické prehľady. 2015 [online]. Available from: http:/ / www.nczisk.sk/ Statisticke_vystupy/ Tematicke_statisticke_vystupy/ Onkologia/ Nuklearna_medicina_klinicka_radiacna_onkologia/ Pages/ default.aspx.
  10. NCZI SK. Činnosť nukleárnej medicíny, klinickej a radiačnej onkológie v SR. Štatistické prehľady. 2016 [online]. Available from: http:/ / www.nczisk.sk/ Statisticke_vystupy/ Tematicke_statisticke_vystupy/ Onkologia/ Nuklearna_medicina_klinicka_radiacna_onkologia/ Pages/ default.aspx.
  11. NCZI SK. Činnosť nukleárnej medicíny, klinickej a radiačnej onkológie v SR. Štatistické prehľady. 2017 [online]. Available from: http:/ / www.nczisk.sk/ Statisticke_vystupy/ Tematicke_statisticke_vystupy/ Onkologia/ Nuklearna_medicina_klinicka_radiacna_onkologia/ Pages/ default.aspx.
  12. Mattsson S, Johansson L, Svegborn SL et al.Radiation dose to patients from radiopharmaceuticals: a compendium of current information related to frequently used substances. Ann ICRP 2015; 44(2 Suppl): 7–321. doi: 10.1177/ 04664 5314558019.
  13. Donohoe KJ, Maurer AH, Ziessman HA et al. Procedure guideline for adult solid-meal gastric-emptying study 3.0*. J Nucl Med Technol 2009; 37(3): 196–200. doi: 10.2967/ jnmt.109.067843.
  14. Mettler FA Jr, Huda W, Yoshizumi TT et al. Effective doses in radiology and dia­gnostic nuclear medicine: a catalog. Radiology 2008; 248(1): 254–263. doi: 10.1148/ radiol.24 81071451.
  15. St Vincent’s Hospital Sydney. Gastric emptying scan. 2015 [online]. Available from: http:/ / www.anzctr.org.au/ AnzctrAttachments/ 370723-Scintigraphy%20protocol.pdf.
  16. Knight LC. Update on gastrointestinal radiopharmaceuticals and dosimetry estimates. Semin Nucl Med 2012; 42(2): 138––144. doi: 10.1053/ j.semnuclmed.2011.11.001.
Labels
Paediatric gastroenterology Gastroenterology and hepatology Surgery

Article was published in

Gastroenterology and Hepatology

Issue 2

2021 Issue 2

Most read in this issue
Login
Forgotten password

Enter the email address that you registered with. We will send you instructions on how to set a new password.

Login

Don‘t have an account?  Create new account

#ADS_BOTTOM_SCRIPTS#