Czech and Slovak Ophthalmology
Incidence of Retractive Errors with Corrective Aids Subsequent Selection
This study follows the occurrence of refractive errors in population and the possible selection of the appropriate type of corrective aids. Objective measurement and subsequent...
Authors: Beneš P., Synek S., Petrová S., Sokolová Šidlová J., Forýtková L., Holoubková Z.
Issue: 1/2012
Read article locked
Floppy Eyelid Syndrome and Obstructive Sleep Apnoea
Floppy eyelid syndrome (FES) is a relatively rare condition of unknown aetiology, commonly described in association with other systemic conditions, particularly with...
Authors: Karhanová M., Hobzová M., Marešová K.
Issue: 1/2012
Read article locked
Effects of Intravitreal Pegaptanib or Bevacizumab and Laser in Treatment of Threshold Retinopathy of Prematurity in Zone I and Posterior Zone II – Four Years Results
Purpose: To evaluate efficacy and safety of intravitreal injection of pegaptanib or bevacizumab and laser photocoagulation for treatment of threshold stage 3+ retinopathy of...
Authors: Autrata R., Šenková K., Holoušová M., Krejčířová I., Doležel Z., Borek I.
Issue: 1/2012
Read article locked
Comparative Study of Intraocular Pressure Measurements by Goldmann Applanation Tonometer, Noncontact Tonometer and TonoPen
The purpose of the study was to compare the levels of the intraocular pressure (NOT) measured in one eye at the same moment by three different methods: by Goldmann applanation...
Authors: Česká Burdová M., Ferrová K., Filouš A., Oskorypová K., Ležatková P., Sedláčková P.
Issue: 1/2012
Read article locked
Selected Prognostic Factors of Malignant Uveal Melanoma
Malignant uveal melanoma is the most common intraocular tumor in adults. Despite very good local treatment results, patients` survival has not improved in the last decades...
Authors: Svetlošáková Z., Krásnik V., Gergišáková H., Babál P., Kusenda P.
Issue: 1/2012
Read article locked
Selection of CzMA JEP journals
Display all journals
Most read
- Contribution to the Investigation Macular Function for the Surgical Treatment of Idiopathic Macular Holes | views: 101
- Correlation of Intraocular Pressure Measured by Applanation Tonometry, Noncontact Tonometry and TonoPen with Central Corneal Thickness | views: 98
- Posterior Capsule Opacification in Long-term Follow-up of Patients after Implantation of Hydrophilic / Hydrophobic Intraocular Lens Acri.Smart | views: 93
- Spontaneous Closure of Idiopathic Macular Hole (Presentation of 4 Cases) | views: 87
- AquaLase Method – Influence to the Secondary Cataract Appearance and its Safety | views: 74
- Suprachoroid Hemorrhage without the Connection to the Surgical Procedure | views: 69
- Comparison of Keratometric Values and Corneal Eccentricity of Myopia, Hyperopia and Emmetropia | views: 67
- Transcaruncular Medial Orbitotomy – a Case Report | views: 58
- Minimal Ocular Findings in a Patient with Best Disease Caused by the c.653G>A Mutation in BEST1 | views: 45
- Results of the IOP Decrease after Application of Some Mixtures of Amino Acids and Antiglaucomatics in Rabbits (A Review of Experimental Publications) | views: 43
